Quantifying the effect of resin type and sterilization method on the degradation of ultrahigh molecular weight polyethylene after 4 years of real-time shelf aging.

Bettina M Willie1, Shadi Ashrafi, Sanjin Alajbegovic, Trever Burnett, Roy D Bloebaum.   

Abstract

Alternative sterilization methods including ethylene oxide, gas plasma, and gamma-radiation in an inert environment were implemented in the late 1990s, to limit oxidative degradation of ultrahigh molecular weight polyethylene (PE). There was also a simultaneous transition to PE resins that did not contain calcium stearate. Shelf storage duration of PE inserts following gamma-irradiation in air has been correlated to poor clinical performance and increased wear. This study aimed to determine how sterilization method and resin type influenced degradation of PE after 4 years of real-time shelf aging. It was hypothesized that gamma-irradiation and stearate containing resins would incur significantly more degradation than nonradiated, stearate-free resins. Gamma-irradiated PE samples in air and nitrogen had a significantly increased density and oxidation index, compared to nonirradiated PE after 4 years of shelf aging. Alternative sterilization methods such as ethylene oxide and gas plasma appeared to have significantly less oxidation regardless of PE resin type. A partial correlation demonstrated that density and oxidation index were not correlated (r(2) = 0.079) when examining the influence of sterilization method. The data supported that after 4 years of real-time shelf aging, the type of sterilization method had a larger influence on PE degradation than resin type. Copyright 2004 Wiley Periodicals, Inc. J Biomed Mater Res 69A: 477-489, 2004

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15127395     DOI: 10.1002/jbm.a.30018

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  2 in total

1.  Oxidation and wear of 100-Mrad cross-linked polyethylene shelf-aged for 30 years.

Authors:  Hironobu Oonishi; Sok Chol Kim; Hiroyuki Oonishi; Masayuki Kyomoto; Shingo Masuda
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

2.  Equivalent wear performance of dual mobility bearing compared with standard bearing in total hip arthroplasty: in vitro study.

Authors:  Gaël Gaudin; André Ferreira; Romain Gaillard; Jean Louis Prudhon; Jacques H Caton; Sébastien Lustig
Journal:  Int Orthop       Date:  2016-11-22       Impact factor: 3.075

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.