Literature DB >> 15126721

Reliability of biomechanical variables of sprint running.

Joseph P Hunter1, Robert N Marshall, Peter McNair.   

Abstract

PURPOSE: The purpose of this paper was to report the reliability of variables used in the biomechanical assessment of sprint running and to document how these reliability measures are likely to improve when using the average score of multiple trials.
METHODS: Twenty-eight male athletes performed maximal-effort sprints. Video and ground reaction force data were collected at the 16-m mark. The reliability (systematic bias, random error, and retest correlation) for a single score was calculated for 26 kinematic and 7 kinetic variables. In addition, the reliability (random error and retest correlation) for the average score of 2, 3, 4, and 5 trials was predicted from the reliability of a single score.
RESULTS: For all variables, there was no evidence of systematic bias. The measures of random error and retest correlation differed widely among the variables. Variables describing horizontal velocity of the body's center of mass were the most reliable, whereas variables based on vertical displacement of the body's center of mass or braking ground reaction force were the least reliable. For all variables, reliability improved notably when the average score of multiple trials was the measurement of interest.
CONCLUSION: Although it is up to the researcher to judge whether a measurement is reliable enough for its intended use, some of the lower-reliability variables were possibly too unreliable to monitor small changes in an athlete's performance. Nonetheless, there was a consistent trend for reliability to improve notably when the average score of multiple trials was the measurement of interest. Subsequently, if resources permit, researchers and applied sports-scientists may like to consider using the average score of multiple trials to gain the advantages that improved reliability offers.

Mesh:

Year:  2004        PMID: 15126721     DOI: 10.1249/01.mss.0000126467.58091.38

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  6 in total

1.  The Biomechanics of Standing Start and Initial Acceleration: Reliability of the Key Determining Kinematics.

Authors:  Regan J Standing; Peter S Maulder
Journal:  J Sports Sci Med       Date:  2017-03-01       Impact factor: 2.988

2.  Reproducibility and variability of the cost functions reconstructed from experimental recordings in multifinger prehension.

Authors:  Xun Niu; Mark L Latash; Vladimir M Zatsiorsky
Journal:  J Mot Behav       Date:  2012-02-24       Impact factor: 1.328

3.  Retest reliability of force-time variables of neck muscles under isometric conditions.

Authors:  Sivan Almosnino; Lucie Pelland; Joan M Stevenson
Journal:  J Athl Train       Date:  2010 Sep-Oct       Impact factor: 2.860

4.  Kinematic and kinetic reliability of two jumping and landing physical performance tasks in young adult women.

Authors:  Alexis Ortiz; Sharon Olson; Charles L Libby; Young-Hoo Kwon; Elaine Trudelle-Jackson
Journal:  N Am J Sports Phys Ther       Date:  2007-05

5.  Assessment of Correlation between Electrogoniometer Measurements and Sports-Specific Movement in Karate Elites.

Authors:  Sara Lotfian; Afsaneh Safar Cherati; Aliashraf Jamshidi; Mohammad Ali Sanjari
Journal:  Asian J Sports Med       Date:  2014-06

6.  Joint Torque and Mechanical Power of Lower Extremity and Its Relevance to Hamstring Strain during Sprint Running.

Authors:  Yunjian Zhong; Weijie Fu; Shutao Wei; Qing Li; Yu Liu
Journal:  J Healthc Eng       Date:  2017-07-12       Impact factor: 2.682

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.