Literature DB >> 15125156

Fibre-optic array for curvature assessment: application in otitis diagnosis.

M Sundberg1, M Borga, H Knutsson, A Johansson, T Strömberg, P A Oberg.   

Abstract

A contact-free sensor consisting of two parallel optical-fibre arrays was designed to assess surface shapes of diffusely scattering media. By sequentially illuminating objects using one fibre array and detecting the diffusely back-scattered photons by the other, a source-detector intensity matrix was formed, where the matrix element (i, j) was the intensity at detector j when light source i was excited. Experimental data from convex and concave polyacetal plastic surfaces were recorded. A mathematical model was used for simulating source-detector intensity matrices for the surfaces analysed in the experiments. Experimental results from the system were compared with the theoretically expected results provided by the mathematical model. The shape and relative amplitude showed similar behaviour in the experiments and simulations. A convex/concave discriminator index D, representing the detected intensity difference between two source-detector separations, was defined. The relative dynamic range of D, defined as the difference between the maximum and the minimum divided by the mean of the index, was 1.37 for convex surfaces and 0.68 for concave surfaces, at a measuring distance of 4.5 mm. The index D was positive for convex surfaces and negative for concave surfaces, which showed that the system could distinguish between convex and concave surfaces, an important result for the diagnosis of otitis media.

Entities:  

Mesh:

Year:  2004        PMID: 15125156     DOI: 10.1007/bf02344638

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  16 in total

1.  High-resolution imaging of the middle ear with optical coherence tomography: a feasibility study.

Authors:  C Pitris; K T Saunders; J G Fujimoto; M E Brezinski
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2001-06

2.  Topometry of technical and biological objects by fringe projection.

Authors:  R Windecker; H J Tiziani
Journal:  Appl Opt       Date:  1995-07-01       Impact factor: 1.980

3.  Optoelectronic moire projector for real-time shape and deformation studies of the tympanic membrane.

Authors:  J J Dirckx; W F Decraemer
Journal:  J Biomed Opt       Date:  1997-04       Impact factor: 3.170

4.  Otoscopic diagnosis of middle ear effusion in acute and non-acute otitis media. I. The value of different otoscopic findings.

Authors:  P H Karma; M A Penttilä; M M Sipilä; M J Kataja
Journal:  Int J Pediatr Otorhinolaryngol       Date:  1989-02       Impact factor: 1.675

5.  Tympanic membrane. II. Pars flaccida.

Authors:  D J Lim
Journal:  Acta Otolaryngol       Date:  1968-12       Impact factor: 1.494

6.  Human tympanic membrane. An ultrastructural observation.

Authors:  D J Lim
Journal:  Acta Otolaryngol       Date:  1970-09       Impact factor: 1.494

7.  Detection of middle ear effusion by acoustic reflectometry.

Authors:  D W Teele; J Teele
Journal:  J Pediatr       Date:  1984-06       Impact factor: 4.406

8.  Diagnostic certainty for acute otitis media.

Authors:  Richard M Rosenfeld
Journal:  Int J Pediatr Otorhinolaryngol       Date:  2002-06-17       Impact factor: 1.675

9.  Assessing diagnostic accuracy and tympanocentesis skills by nurse practitioners in management of otitis media.

Authors:  A Sorrento; M E Pichichero
Journal:  J Am Acad Nurse Pract       Date:  2001-11

10.  Diagnostic value of tympanometry in infants in clinical practice.

Authors:  A Palmu; H Puhakka; T Rahko; A K Takala
Journal:  Int J Pediatr Otorhinolaryngol       Date:  1999-08-20       Impact factor: 1.675

View more
  1 in total

1.  A bench-top model of middle ear effusion diagnosed with optical tympanometry.

Authors:  Samir Shreim; Mehdi Abouzari; John Weidling; Sean White; Khodayar Goshtasbi; Nguyen Pham; Hamid R Djalilian; Elliot Botvinick
Journal:  Int J Pediatr Otorhinolaryngol       Date:  2020-04-20       Impact factor: 1.675

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.