Literature DB >> 15125009

Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams.

Antonis Tzedakis1, John E Damilakis, Michael Mazonakis, John Stratakis, Haralambos Varveris, Nicholas Gourtsoyiannis.   

Abstract

Our aim in the present study was to investigate the effects of initial electron beam characteristics on Monte Carlo calculated absorbed dose distribution for a linac 6 MV photon beam. Moreover, the range of values of these parameters was derived, so that the resulted differences between measured and calculated doses were less than 1%. Mean energy, radial intensity distribution and energy spread of the initial electron beam, were studied. The method is based on absorbed dose comparisons of measured and calculated depth-dose and dose-profile curves. All comparisons were performed at 10.0 cm depth, in the umbral region for dose-profile and for depths past maximum for depth-dose curves. Depth-dose and dose-profile curves were considerably affected by the mean energy of electron beam, with dose profiles to be more sensitive on that parameter. The depth-dose curves were unaffected by the radial intensity of electron beam. In contrast, dose-profile curves were affected by the radial intensity of initial electron beam for a large field size. No influence was observed in dose-profile or depth-dose curves with respect to energy spread variations of electron beam. Conclusively, simulating the radiation source of a photon beam, two of the examined parameters (mean energy and radial intensity) of the electron beam should be tuned accurately, so that the resulting absorbed doses are within acceptable precision. The suggested method of evaluating these crucial but often poorly specified parameters may be of value in the Monte Carlo simulation of linear accelerator photon beams.

Mesh:

Year:  2004        PMID: 15125009     DOI: 10.1118/1.1668551

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  Dosimetric verification of the anisotropic analytical algorithm in lung equivalent heterogeneities with and without bone equivalent heterogeneities.

Authors:  Kaoru Ono; Satoru Endo; Kenichi Tanaka; Masaharu Hoshi; Yutaka Hirokawa
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

2.  Monte Carlo dose calculations for a 6-MV photon beam in a thorax phantom.

Authors:  Alireza Farajollahi; Asghar Mesbahi
Journal:  Radiat Med       Date:  2006-05

3.  The effect of energy spectrum change on DNA damage in and out of field in 10-MV clinical photon beams.

Authors:  A O Ezzati; Y Xiao; M Sohrabpour; M T Studenski
Journal:  Med Biol Eng Comput       Date:  2014-10-29       Impact factor: 2.602

4.  Commissioning of 6 MV medical linac for dynamic MLC-based IMRT on Monte Carlo code GEANT4.

Authors:  Hiroyuki Okamoto; Yukio Fujita; Kyoko Sakama; Hidetoshi Saitoh; Tatsuaki Kanai; Jun Itami; Toshiyuki Kohno
Journal:  Radiol Phys Technol       Date:  2014-02-08

5.  Monte Carlo Simulation of Siemens ONCOR Linear Accelerator with BEAMnrc and DOSXYZnrc Code.

Authors:  Keyvan Jabbari; Hossein Saberi Anvar; Mohammad Bagher Tavakoli; Alireza Amouheidari
Journal:  J Med Signals Sens       Date:  2013-07

6.  Determination of initial electron parameters by means of Monte Carlo simulations for the Siemens Artiste Linac 6 MV photon beam.

Authors:  Taylan Tuğrul; Osman Eroğul
Journal:  Rep Pract Oncol Radiother       Date:  2019-05-31

7.  Monte Carlo commissioning of radiotherapy LINAC-Introducing an improved methodology.

Authors:  Saqib Bajwa; Attia Gul; Shahbaz Ahmed; Muhammad B Kakakhel
Journal:  Rep Pract Oncol Radiother       Date:  2020-06-30

Review 8.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

9.  Moving GPU-OpenCL-based Monte Carlo dose calculation toward clinical use: Automatic beam commissioning and source sampling for treatment plan dose calculation.

Authors:  Zhen Tian; Yongbao Li; Nima Hassan-Rezaeian; Steve B Jiang; Xun Jia
Journal:  J Appl Clin Med Phys       Date:  2017-02-16       Impact factor: 2.102

10.  Monte Carlo Study of Fetal Dosimetry Parameters for 6 MV Photon Beam.

Authors:  Maryam Atarod; Parvaneh Shokrani
Journal:  J Med Signals Sens       Date:  2013-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.