Literature DB >> 15125000

Introduction of a novel dose saving acquisition mode for the PortalVision aS500 EPID to facilitate on-line patient setup verification.

D Vetterli1, H Riem, D M Aebersold, R H Greiner, P Manser, P Cossmann, L Kemmerling, E J Born, R Mini.   

Abstract

In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensure that the planned dosimetric coverage of the tumor volume is actually realized in the patient. Since the direction of setup fields often deviates from the direction of the treatment beams, extra dose is delivered to the patient during the acquisition of these portal images which may reach clinical relevance. The aim of this work was to develop a new acquisition mode for the PortalVision aS500 electronic portal imaging device from Varian Medical Systems that allows one to take portal images with reduced dose while keeping good image quality. The new acquisition mode, called RadMode, selectively enables and disables beam pulses during image acquisition allowing one to stop wasting valuable dose during the initial acquisition of "reset frames." Images of excellent quality can be taken with 1 MU only. This low dose per image facilitates daily setup verification with considerably reduced extra dose.

Entities:  

Mesh:

Year:  2004        PMID: 15125000     DOI: 10.1118/1.1668391

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Analysis of fiducial markers used for on-line verification in the external-beam radiotherapy of patients with cranial tumours.

Authors:  R Ma Cañón; I Azinovic; M Lobato; J Navarro; J Rebollo
Journal:  Clin Transl Oncol       Date:  2007-08       Impact factor: 3.405

2.  Dose optimisation during imaging in radiotherapy.

Authors:  P Ravindran
Journal:  Biomed Imaging Interv J       Date:  2007-04-01

3.  Acute and late toxicity in prostate cancer patients treated by dose escalated intensity modulated radiation therapy and organ tracking.

Authors:  Pirus Ghadjar; Jacqueline Vock; Daniel Vetterli; Peter Manser; Roland Bigler; Jan Tille; Axel Madlung; Frank Behrensmeier; Roberto Mini; Daniel M Aebersold
Journal:  Radiat Oncol       Date:  2008-10-20       Impact factor: 3.481

4.  Performance optimization of the Varian aS500 EPID system.

Authors:  Lucie Berger; Pascal François; Geneviève Gaboriaud; Jean-Claude Rosenwald
Journal:  J Appl Clin Med Phys       Date:  2006-02-15       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.