Literature DB >> 15123353

In vivo real-time microangiography of the liver in mice using synchrotron radiation.

Shogo Kobayashi1, Masatoshi Hori, Keizo Dono, Hiroaki Nagano, Koji Umeshita, Shoji Nakamori, Masato Sakon, Keigo Osuga, Keiji Umetani, Takamichi Murakami, Hironobu Nakamura, Morito Monden.   

Abstract

BACKGROUND/AIMS: The aim of this study was to visualize hepatic microvessels (less than 100 microm in diameter) in vivo, which could not be visualized by conventional X-ray angiography, by using synchrotron radiation (ultra-bright and monochromatic X-ray).
METHODS: Five female Balb/c nu/nu mice were used. To investigate the hepatic microvessels under nearly physiologic conditions, we performed in vivo aortography under anesthesia with 370 mgI/ml nonionic iodine contrast medium using monochromatic 17-keV X-rays generated by a synchrotron. Images were captured with a pixel matrix size of 1024 x 1024 at a rate of 30 pictures/s. The field of view was 7 mm x 7 mm and thus the pixel size was approximately 7 microm. Captured images were evaluated both qualitatively and quantitatively.
RESULTS: Small hepatic arterial and portal venous branches of the liver were visualized separately during one sequential aortogram. The minimum diameter of the vessels observed was approximately 20 microm, and the vessels which ran parallel to the hepatic artery were observed and it seemed to be intrahepatic peribiliary arterial plexus.
CONCLUSIONS: Our new experimental model would be useful for visualization of changes in the hepatic microcirculation under nearly physiologic conditions.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15123353     DOI: 10.1016/j.jhep.2003.11.029

Source DB:  PubMed          Journal:  J Hepatol        ISSN: 0168-8278            Impact factor:   25.083


  10 in total

1.  A method for serial selective arterial catheterization and digital subtraction angiography in rodents.

Authors:  A Buhalog; R Yasuda; D Consigny; K Maurer; C M Strother
Journal:  AJNR Am J Neuroradiol       Date:  2010-05-20       Impact factor: 3.825

2.  Tomographic digital subtraction angiography for lung perfusion estimation in rodents.

Authors:  Cristian T Badea; Laurence W Hedlund; Ming De Lin; Julie S Boslego Mackel; Ehsan Samei; G Allan Johnson
Journal:  Med Phys       Date:  2007-05       Impact factor: 4.071

3.  A high-precision contrast injector for small animal x-ray digital subtraction angiography.

Authors:  Ming de Lin; Lutao Ning; Cristian T Badea; Nilesh N Mistry; Yi Qi; G Allan Johnson
Journal:  IEEE Trans Biomed Eng       Date:  2008-03       Impact factor: 4.538

4.  Three-dimensional visualization of microvasculature from few-projection data using a novel CT reconstruction algorithm for propagation-based X-ray phase-contrast imaging.

Authors:  Yuqing Zhao; Dongjiang Ji; Yimin Li; Xinyan Zhao; Wenjuan Lv; Xiaohong Xin; Shuo Han; Chunhong Hu
Journal:  Biomed Opt Express       Date:  2019-12-20       Impact factor: 3.732

5.  Molecular evaluation of thrombosis using X-ray phase contrast imaging with microbubbles targeted to P-selectin in mice.

Authors:  Rongbiao Tang; Wei-Min Chai; Fuhua Yan; Guo-Yuan Yang; Ke-Min Chen
Journal:  Eur Radiol       Date:  2015-12-02       Impact factor: 5.315

Review 6.  Whole animal imaging.

Authors:  Gurpreet Singh Sandhu; Luis Solorio; Ann-Marie Broome; Nicolas Salem; Jeff Kolthammer; Tejas Shah; Chris Flask; Jeffrey L Duerk
Journal:  Wiley Interdiscip Rev Syst Biol Med       Date:  2010 Jul-Aug

Review 7.  In vivo small-animal imaging using micro-CT and digital subtraction angiography.

Authors:  C T Badea; M Drangova; D W Holdsworth; G A Johnson
Journal:  Phys Med Biol       Date:  2008-08-29       Impact factor: 3.609

8.  Mouse Hepatic Tumor Vascular Imaging by Experimental Selective Angiography.

Authors:  Sang Kyum Kim; Honsoul Kim; Gou Young Koh; Dae-Sik Lim; Dae-Yeul Yu; Man Deuk Kim; Mi-Suk Park; Joon Seok Lim
Journal:  PLoS One       Date:  2015-07-01       Impact factor: 3.240

9.  Using synchrotron radiation angiography with a highly sensitive detector to identify impaired peripheral perfusion in rat pulmonary emphysema.

Authors:  Hiromichi Ito; Shonosuke Matsushita; Kazuyuki Hyodo; Yukio Sato; Yuzuru Sakakibara
Journal:  J Synchrotron Radiat       Date:  2013-02-08       Impact factor: 2.616

10.  In-line phase contrast imaging of hepatic portal vein embolization with radiolucent embolic agents in mice: a preliminary study.

Authors:  Rongbiao Tang; Wei Huang; Fuhua Yan; Yong Lu; Wei-Min Chai; Guo-Yuan Yang; Ke-Min Chen
Journal:  PLoS One       Date:  2013-12-04       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.