Literature DB >> 15122690

Fast, three-dimensional free-breathing MR imaging of myocardial infarction: a feasibility study.

Manojkumar Saranathan1, Carlos E Rochitte, Thomas K F Foo.   

Abstract

Imaging delayed hyperenhancement of myocardial infarction is most commonly performed using an inversion recovery (IR) prepared 2D breathhold segmented k-space gradient echo (FGRE) sequence. Since only one slice is acquired per breathhold in this technique, 12-16 successive breathholds are required for complete anatomical coverage of the heart. This prolongs the overall scan time and may be exhausting for patients. A navigator-echo gated, free-breathing, 3D FGRE sequence is proposed that can be used to acquire a single slab covering the entire heart with high spatial resolution. The use of a new variable sampling in time (VAST) acquisition scheme enables the entire 3D volume to be acquired in 1.5-2 min, minimizing artifacts from bulk motion and diaphragmatic drift and contrast variations due to contrast media washout. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15122690     DOI: 10.1002/mrm.20061

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  Clinical performance of high-resolution late gadolinium enhancement imaging with compressed sensing.

Authors:  Tamer A Basha; Mehmet Akçakaya; Charlene Liew; Connie W Tsao; Francesca N Delling; Gifty Addae; Long Ngo; Warren J Manning; Reza Nezafat
Journal:  J Magn Reson Imaging       Date:  2017-03-16       Impact factor: 4.813

2.  Volumetric late gadolinium-enhanced myocardial imaging with retrospective inversion time selection.

Authors:  Steve Kecskemeti; Kevin Johnson; Christopher J François; Mark L Schiebler; Orhan Unal
Journal:  J Magn Reson Imaging       Date:  2013-02-06       Impact factor: 4.813

Review 3.  Cardiac imaging techniques for physicians: late enhancement.

Authors:  Peter Kellman; Andrew E Arai
Journal:  J Magn Reson Imaging       Date:  2012-09       Impact factor: 4.813

4.  Recurrence of atrial fibrillation correlates with the extent of post-procedural late gadolinium enhancement: a pilot study.

Authors:  Dana C Peters; John V Wylie; Thomas H Hauser; Reza Nezafat; Yuchi Han; Jeong Joo Woo; Jason Taclas; Kraig V Kissinger; Beth Goddu; Mark E Josephson; Warren J Manning
Journal:  JACC Cardiovasc Imaging       Date:  2009-03

5.  Free breathing three-dimensional late gadolinium enhancement cardiovascular magnetic resonance using outer volume suppressed projection navigators.

Authors:  Rajiv G Menon; G Wilson Miller; Jean Jeudy; Sanjay Rajagopalan; Taehoon Shin
Journal:  Magn Reson Med       Date:  2016-04-28       Impact factor: 4.668

6.  Inversion-recovery single-shot cardiac MRI for the assessment of myocardial infarction at 1.5 T with a dedicated cardiac coil.

Authors:  M Wildgruber; M Settles; K Herrmann; A J Beer; E J Rummeny; A M Huber
Journal:  Br J Radiol       Date:  2012-09       Impact factor: 3.039

7.  3D late gadolinium enhancement in a single prolonged breath-hold using supplemental oxygenation and hyperventilation.

Authors:  Sébastien Roujol; Tamer A Basha; Mehmet Akçakaya; Murilo Foppa; Raymond H Chan; Kraig V Kissinger; Beth Goddu; Sophie Berg; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2013-10-15       Impact factor: 4.668

8.  Free-breathing 3D late gadolinium enhancement imaging of the left ventricle using a stack of spirals at 3T.

Authors:  Iain T Pierce; Jennifer Keegan; Peter Drivas; Peter D Gatehouse; David N Firmin
Journal:  J Magn Reson Imaging       Date:  2014-05-03       Impact factor: 4.813

Review 9.  Cardiovascular magnetic resonance physics for clinicians: Part II.

Authors:  John D Biglands; Aleksandra Radjenovic; John P Ridgway
Journal:  J Cardiovasc Magn Reson       Date:  2012-09-20       Impact factor: 5.364

10.  Diffuse myocardial fibrosis in hypertrophic cardiomyopathy can be identified by cardiovascular magnetic resonance, and is associated with left ventricular diastolic dysfunction.

Authors:  Andris H Ellims; Leah M Iles; Liang-han Ling; James L Hare; David M Kaye; Andrew J Taylor
Journal:  J Cardiovasc Magn Reson       Date:  2012-10-29       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.