Capture management efficacy in children and young adults with endocardial and unipolar epicardial systems.

Mitchell I Cohen1, Karen Buck, Ronn E Tanel, Victoria L Vetter, Larry A Rhodes, James Cox, Todd Sheldon, Linda Ruetz.   

Abstract

AIMS: This prospective study characterized performance of the Kappa 700 Ventricular Capture Management trade mark (VCM) system for monitoring ventricular pacing threshold and adapting outputs in both endocardial and unipolar epicardial pacing systems in children and young adults. VCM bears cautionary labelling against use with epicardial leads since they have not been demonstrated appropriate for use with VCM. METHODS AND
RESULTS: VCM was programmed in "Monitor Only" mode. Ventricular pacemaker thresholds were measured daily using VCM for a minimum of 2 months. Potential device longevities at nominal outputs (3.5 V, 1.0 ms) and at VCM-recommended outputs were compared. Thirty patients (median age 14.4 years (1-27 years); 15 epicardial/15 endocardial) completed the study. During the daily measurements, consistent undersensed evoked response occurred in 2 patients (Medtronic epicardial leads 4965). For the other 28 patients, programming VCM in "Adaptive" mode from implant would provide an additional 6.8 months (0-19 months) of battery life.
CONCLUSION: Although not an IDE (Investigation Device Exemption) study, this study showed acceptable VCM performance in "Monitor Only" mode in 13/15 patients with unipolar epicardial leads. A 2-month "Monitor Only" observation period helps screen patients who might not benefit from VCM. VCM may provide substantial energy savings and extended battery life for children and young adults. Copyright 2004 The European Society of Cardiology

Entities:  

Mesh:

Year:  2004        PMID: 15121079     DOI: 10.1016/j.eupc.2004.02.001

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  2 in total

1.  Manual vs. automatic capture management in implantable cardioverter defibrillators and cardiac resynchronization therapy defibrillators.

Authors:  Francis D Murgatroyd; Erhard Helmling; Bernd Lemke; Bernd Eber; Christian Mewis; Judith van der Meer-Hensgens; Yanping Chang; Vladimir Khalameizer; Amos Katz
Journal:  Europace       Date:  2010-03-14       Impact factor: 5.214

2.  A Cautionary Tale on Atrial Capture Management, Biventricular Pacing, and Recurrent Asystole.

Authors:  Christopher L Johnsrude; Kelvin C Lau
Journal:  J Innov Card Rhythm Manag       Date:  2019-10-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.