Literature DB >> 15120013

Determining factors of aerosol deposition for four pMDI-spacer combinations in an infant upper airway model.

Hettie M Janssens1, Arno Krijgsman, Ton F M Verbraak, Wim C J Hop, Johan C de Jongste, Harm A W M Tiddens.   

Abstract

The aim of this study was to measure and compare the influence of tidal volume (Vt) respiratory rate (RR) and pMDI/spacer combination on aerosol deposition of 4 pMDI/spacer combinations, which are used for infants. An anatomically correct upper airway model of a 9-month-old infant was connected to a breathing simulator. Sinusoidal breathing patterns were simulated with; duty cycle T(i)/T(tot) = 0.42, Vt: 25, 50, 75, 100, 150, 200 ml (RR: 30 breaths/min); and RR: 20, 30, 42, 60, 78 breaths/min (Vt: 100 mL). pMDI/Spacers tested were: budesonide 200 microg/Nebuchamber, fluticasone 125 microg/Babyhaler and both budesonide and fluticasone with Aerochamber. Plastic spacers were detergent coated to reduce electrostatic charge. Spacer-output and lung dose were measured by a filter positioned between spacer and facemask or between model and breathing simulator. Particle size distribution of lung dose was assessed with an impactor during simulated breathing. Spacer-output was significantly positively correlated with Vt for all pMDI/spacers (all R > 0.77, p < 0.001), but not correlated with RR. Lung doses initially increased from Vt = 25 to 50 mL (Nebuchamber, Aerochamber) or to 100 mL (Babyhaler) and then decreased, with increasing Vt and RR (R: -0.98 to -0.82, p < 0.001). Lung doses of fluticasone were 1.5-6-fold higher compared with budesonide, irrespective of spacer type (p < 0.001). MMAD decreased with increasing Vt and RR. Dose to the lungs of particles <2.1 microm was independent of Vt and RR. Lung dose decreases with increasing inspiratory flow (increasing Vt or RR) by increasing impaction of coarse particles in the upper airways. Deposition of particles <2.1 microm is relatively flow independent. When electrostatic charge of spacers is reduced, lung dose is pMDI dependent and spacer independent.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15120013     DOI: 10.1089/089426804322994460

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  8 in total

1.  Incentive device improves spacer technique but not clinical outcome in preschool children with asthma.

Authors:  André Schultz; Peter D Sly; Guicheng Zhang; André Venter; Peter N Le Souëf; Sunalene G Devadason
Journal:  J Paediatr Child Health       Date:  2011-11-01       Impact factor: 1.954

2.  Deposition of albuterol aerosol generated by pneumatic nebulizer in the Sophia Anatomical Infant Nose-Throat (SAINT) model.

Authors:  Beth L Laube; Gail Sharpless; Charles Shermer; Omer Nasir; Vincent Sullivan; Kenneth Powell
Journal:  Pharm Res       Date:  2010-05-22       Impact factor: 4.200

3.  Croup in the paediatric emergency department.

Authors:  Candice L Bjornson; David W Johnson
Journal:  Paediatr Child Health       Date:  2007-07       Impact factor: 2.253

4.  Valved holding chamber drug delivery is dependent on breathing pattern and device design.

Authors:  Péter Csonka; Lauri Lehtimäki
Journal:  ERJ Open Res       Date:  2019-02-04

5.  Airway gene transfer using cationic emulsion as a mucosal gene carrier.

Authors:  Tae Woo Kim; Hesson Chung; Ick Chan Kwon; Ha Chin Sung; Byung Chul Shin; Seo Young Jeong
Journal:  J Gene Med       Date:  2005-06       Impact factor: 4.565

Review 6.  Lung Deposition and Inspiratory Flow Rate in Patients with Chronic Obstructive Pulmonary Disease Using Different Inhalation Devices: A Systematic Literature Review and Expert Opinion.

Authors:  Adolfo Baloira; Araceli Abad; Antonia Fuster; Juan Luis García Rivero; Patricia García-Sidro; Eduardo Márquez-Martín; Marta Palop; Néstor Soler; J L Velasco; Fernando González-Torralba
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2021-04-19

Review 7.  Optimal administration of bronchodilators with valved holding chambers in preschool children: a review of literature.

Authors:  Péter Csonka; Terhi Tapiainen; Mika J Mäkelä; Lauri Lehtimäki
Journal:  Eur J Pediatr       Date:  2021-04-20       Impact factor: 3.183

Review 8.  Croup.

Authors:  Candice L Bjornson; David W Johnson
Journal:  Lancet       Date:  2008-01-26       Impact factor: 79.321

  8 in total