Literature DB >> 15119711

Comparison of laboratory and clinical wear rates of resin composites.

Wayne W Barkmeier1, Mark A Latta, Robert L Erickson, Paul Lambrechts.   

Abstract

OBJECTIVE: The purpose of this study was to use wear simulation to develop wear rates for two modern composite systems and then compare these rates with clinical studies on the same materials. METHOD AND MATERIALS: A spring-loaded piston wear simulator was used to generate localized wear rates for P50 and Z100 at 100,000, 200,000, 300,000, and 400,000 cycles. Clinical studies on P50 and Z100 conducted at Creighton University and the Catholic University of Leuven were used for comparison of clinical wear to the laboratory values. Regression analysis was employed to define the wear rates.
RESULTS: The laboratory wear rates determined with simulation for P50 and Z100 were similar. Clinical occlusal contact area (OCA) wear for P50 and Z100 had small differences and were pooled to provide comparison with laboratory data. Wear rates determined from linear regression analysis provided equivalency factors between laboratory localized wear and clinical OCA wear that could be used for future studies. Further regression analysis comparing OCA and generalized clinical wear allowed a conversion factor of 4.5 to be determined.
CONCLUSION: Localized wear from laboratory simulation may be a useful predictor of localized clinical wear and also clinical generalized wear using a conversion factor.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15119711

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  4 in total

1.  Characterization of third-body media particles and their effect on in vitro composite wear.

Authors:  Nathaniel C Lawson; Deniz Cakir; Preston Beck; Mark S Litaker; John O Burgess
Journal:  Dent Mater       Date:  2012-05-10       Impact factor: 5.304

2.  In-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years.

Authors:  Gintare Burian; Kurt Erdelt; Josef Schweiger; Christine Keul; Daniel Edelhoff; Jan-Frederik Güth
Journal:  Sci Rep       Date:  2021-07-07       Impact factor: 4.379

Review 3.  Wear of resin composites: Current insights into underlying mechanisms, evaluation methods and influential factors.

Authors:  Akimasa Tsujimoto; Wayne W Barkmeier; Nicholas G Fischer; Kie Nojiri; Yuko Nagura; Toshiki Takamizawa; Mark A Latta; Masashi Miazaki
Journal:  Jpn Dent Sci Rev       Date:  2017-12-11

4.  Wear resistance of indirect composite resins used for provisional restorations supported by implants.

Authors:  Akimasa Tsujimoto; Carlos Jurado; Jose Villalobos-Tinoco; Wayne Barkmeier; Nicholas Fischer; Toshiki Takamizawa; Mark Latta; Masashi Miyazaki
Journal:  J Adv Prosthodont       Date:  2019-08-27       Impact factor: 1.904

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.