OBJECTIVE: To assess if application of fibrin glue sealant to the peritoneal cuff suture is useful in the prevention of early dialysate leakage in children with end-stage renal disease on chronic peritoneal dialysis (CPD). DESIGN: Single-center, open-label, prospective randomized study. SETTING:University Pediatric Hospital. METHODS:52 catheters were implanted in 45 children (mean age 6.2 +/- 4.5 years). Catheters were randomly assigned to either the control group or the sealant group. In the latter group, 1 mL of fibrin glue sealant was applied to the peritoneal cuff suture. 18 catheters were used for the first time within 5 days after implantation (early-used catheters). Leakage, exit-site or tunnel infection, peritonitis, and adverse secondary effects were evaluated during the initial 60 days after implantation. RESULTS: No adverse secondary effects were seen after the application of the fibrin glue sealant. The incidence of exit/tunnel infection and peritonitis was similar in the two groups. The incidence of leakage was significantly lower in the sealant group (p < 0.02). In the early-used catheters, leakage was detected in 9% of the catheters in the sealant group and in 57% of the control group (p < 0.05). CONCLUSIONS: The application of 1 mL of fibrin glue to the peritoneal cuff suture prevented early dialysate leakage without secondary adverse effects in children on CPD.
RCT Entities:
OBJECTIVE: To assess if application of fibrin glue sealant to the peritoneal cuff suture is useful in the prevention of early dialysate leakage in children with end-stage renal disease on chronic peritoneal dialysis (CPD). DESIGN: Single-center, open-label, prospective randomized study. SETTING: University Pediatric Hospital. METHODS: 52 catheters were implanted in 45 children (mean age 6.2 +/- 4.5 years). Catheters were randomly assigned to either the control group or the sealant group. In the latter group, 1 mL of fibrin glue sealant was applied to the peritoneal cuff suture. 18 catheters were used for the first time within 5 days after implantation (early-used catheters). Leakage, exit-site or tunnel infection, peritonitis, and adverse secondary effects were evaluated during the initial 60 days after implantation. RESULTS: No adverse secondary effects were seen after the application of the fibrin glue sealant. The incidence of exit/tunnel infection and peritonitis was similar in the two groups. The incidence of leakage was significantly lower in the sealant group (p < 0.02). In the early-used catheters, leakage was detected in 9% of the catheters in the sealant group and in 57% of the control group (p < 0.05). CONCLUSIONS: The application of 1 mL of fibrin glue to the peritoneal cuff suture prevented early dialysate leakage without secondary adverse effects in children on CPD.
Authors: Stephen Haggerty; Scott Roth; Danielle Walsh; Dimitrios Stefanidis; Raymond Price; Robert D Fanelli; Todd Penner; William Richardson Journal: Surg Endosc Date: 2014-10-08 Impact factor: 4.584
Authors: Ari Auron; Steve Simon; Walter Andrews; Linda Jones; Shirley Johnson; Gulam Musharaf; Bradley A Warady Journal: Pediatr Nephrol Date: 2007-01-10 Impact factor: 3.714
Authors: Aleksandra M Zurowska; Michel Fischbach; Alan R Watson; Alberto Edefonti; Constantinos J Stefanidis Journal: Pediatr Nephrol Date: 2012-10-09 Impact factor: 3.714