Literature DB >> 15118800

Development of a sensitivity enhanced multiplexed fluorescence covalent microbead immunosorbent assay (FCMIA) for the measurement of glyphosate, atrazine and metolachlor mercapturate in water and urine.

R E Biagini1, J P Smith, D L Sammons, B A MacKenzie, C A F Striley, S K Robertson, J E Snawder.   

Abstract

Body burdens from exposures to pesticides may be estimated from urinary analyses of pesticide parent/metabolite concentrations. Pesticide applicators and others are often exposed to numerous unrelated pesticides, either sequentially or simultaneously. Classically, body burdens of pesticides are analyzed using chemical/instrumental analysis (CIM) or enzyme immunoassays (EIAs). Both of these technologies can usually be used to quantitate one analyte (or closely related groups of analytes) per analysis. Alternatively, multiple analytes can be measured simultaneously using a multiplexed fluorescence covalent microbead immunoassay (FCMIA). We developed a multiplexed FCMIA to simultaneously measure glyphosate (Gly), atrazine (Atz), and metolachlor mercapturate (MM) in water and urine. The assay had least detectable doses (LDDs) in water/diluted urine of 0.11/0.09 ng/ml (Gly, water/urine LDD), 0.10/0.07 ng/ml (Atz) and 0.09/0.03 ng/ml (MM). The sensitivity for the measurement of Gly was enhanced by derivatization. All assays gave linear responses from the LDDs for each respective pesticide to 300 ng/ml. There was no cross-reactivity between the three analytes. Using a 96-well microplate and an autosampler, as many as 288 separate analyses can be completed in approximately 120 min with precision, sensitivity, and specificity equivalent to, if not better, than that found when these same analytes are measured by CIM or EIA.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15118800     DOI: 10.1007/s00216-004-2628-8

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

1.  Flow-through immunosensors using antibody-immobilized polymer monoliths.

Authors:  Jikun Liu; Chien-Fu Chen; Chih-Wei Chang; Don L DeVoe
Journal:  Biosens Bioelectron       Date:  2010-06-11       Impact factor: 10.618

2.  Development of a five-plex flow cytometric immunoassay for the simultaneous detection of six coccidiostats in feed and eggs.

Authors:  Monique E Bienenmann-Ploum; Anne-Catherine Huet; Katrina Campbell; Terence L Fodey; Ursula Vincent; Willem Haasnoot; Philippe Delahaut; Christopher T Elliott; Michel W F Nielen
Journal:  Anal Bioanal Chem       Date:  2012-08-01       Impact factor: 4.142

3.  A magnetic nanoparticles-based method for DNA extraction from the saliva of stroke patients.

Authors:  Li Yi; Ying Huang; Ting Wu; Jun Wu
Journal:  Neural Regen Res       Date:  2013-11-15       Impact factor: 5.135