Literature DB >> 15118209

Bactericidal effects of acidic electrolyzed water on the dental unit waterline.

Shinya Kohno1, Toshitsugu Kawata, Masato Kaku, Tadashi Fuita, Keisuke Tsutsui, Junji Ohtani, Kaoru Tenjo, Masahide Motokawa, Yuiko Tohma, Mao Shigekawa, Hiroko Kamata, Kazuo Tanne.   

Abstract

Many studies have been conducted in the United States regarding the microbial contamination of dental unit waterline, but not in Japan. Recently, acidic electrolyzed water has been used in the medical and dental fields. In this study, we investigated the bactericidal effects of the temporary inflow of acidic electrolyzed water on microbial contamination of the dental unit waterline. First, in order to observe the daily bacterial contamination of the dental unit waterline, water samples were collected at the end of handpieces and three-way syringes before the inflow of acidic electrolyzed water. They were cultured to detect viable bacteria. Later, the inflow of acidic electrolyzed water was conducted through the piping box of the dental unit. Before starting operation on next day, water samples were collected and cultured, as described above. The mean viable bacteria count was 910 -/+ 190 CFU/ml at the end of handpieces, and 521 -/+ 116 CFU/ml at the end of three-way syringes before the inflow of acidic electrolyzed water. However, bacteria were detected in only small numbers at the end of handpieces and three-way syringes on the next day. These results indicated that acidic electrolyzed water could be applied as an appropriate measure against bacterial contamination of the dental unit waterline.

Entities:  

Mesh:

Year:  2004        PMID: 15118209

Source DB:  PubMed          Journal:  Jpn J Infect Dis        ISSN: 1344-6304            Impact factor:   1.362


  3 in total

1.  Disinfecting the acrylic resin plate using electrolyzed acid water and 2% glutaraldehyde: a comparative microbiological study.

Authors:  K R Jnanadev; C L Satish Babu; S Shilpa Shetty; G P Surendra Kumar; H S Sheetal
Journal:  J Indian Prosthodont Soc       Date:  2011-04-07

2.  Electrolyzed Water Generated On-Site as a Promising Disinfectant in the Dental Office During the COVID-19 Pandemic.

Authors:  Ra'fat Ibrahim Farah; Sanaa Najeh Al-Haj Ali
Journal:  Front Public Health       Date:  2021-04-30

3.  Biological properties of acidic cosmetic water from seawater.

Authors:  Wei-Ting Liao; Tsi-Shu Huang; Chien-Chih Chiu; Jian-Liang Pan; Shih-Shin Liang; Bing-Hung Chen; Shi-Hui Chen; Po-Len Liu; Hui-Chun Wang; Zhi-Hong Wen; Hui-Min Wang; Shu-Wen Hsiao
Journal:  Int J Mol Sci       Date:  2012-05-16       Impact factor: 6.208

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.