| Literature DB >> 15117069 |
Oscar Ezquerro1, Gustavo Ortiz, Begoña Pons, María Teresa Tena.
Abstract
Multiple headspace-solid phase microextraction (MHS-SPME) is a recently developed technique for the quantification of analytes in solid samples that avoids the matrix effect. This method implies several consecutive extractions from the same sample. In this way, the total area corresponding to complete extraction can be directly calculated as the sum of the areas of each individual extraction when the extraction is exhaustive, or through a mathematical equation when it is not exhaustive. In this paper, the quantitative determination of benzene, toluene, ethylbenzene and xylene isomers (BTEX) in a certified soil (RTC-CRM304, LGC Promochem) and in a contaminated soil by multiple HS-SPME coupled to a gas chromatography-flame ionisation detector (GC-FID) is presented. BTEX extraction was carried out using soil suspensions in water at 30 degrees C with a 75 microm carboxen-polydimethylsiloxane (CAR-PDMS) fibre and calibration was carried out using aqueous BTEX solutions at 30 degrees C for 30 min with the same fibre. BTEX concentration was calculated by interpolating the total peak area found for the soils in the calibration graphs obtained from aqueous solutions. The toluene, ethylbenzene, o-xylene and m,p-xylene concentrations obtained were statistically equal to the certified values.Entities:
Mesh:
Substances:
Year: 2004 PMID: 15117069 DOI: 10.1016/j.chroma.2004.02.030
Source DB: PubMed Journal: J Chromatogr A ISSN: 0021-9673 Impact factor: 4.759