Automatic system for noninvasive blood pressure determination in rotary pump recipients.

Heinrich Schima1, Herbert Boehm, Leopold Huber, Helmut Schmallegger, Michael Vollkron, Michael Hiesmayr, Robert Noisser, Georg Wieselthaler.   

Abstract

In patients with implanted rotary pumps, the arterial pressure pulsatility is usually far lower than in normal individuals. Depending on the remaining degree of pulsatility, cuff-based systems such as the classical Riva-Rocci-determination of arterial blood pressure and correlated sounds or pressure measurements based on cuffpressure oscillations become inaccurate or even impossible. Therefore, a system was developed which evaluates the flow in the radial artery using an ultrasound wristwatch sensor, and this additional information is used for pressure determination. A computerized data acquisition and cuff-control system based on a PC using Matlab software, a wristwatch ultrasound device, and a compressor-driven pressure cuff was set up. The cuff was controlled for automatic inflation and deflation cycles. Cuff pressure and arterial flow was recorded. Several algorithm strategies were developed, which gave data for systolic blood pressure and heart rate together with a reliability index for data quality. Finally, the new algorithms were implemented in a microcontroller system. Comparisons with invasive measurements showed excellent correlation with systolic blood pressure (mean deltaP -0.3 mm Hg, n = 28). During exercise of rotary pump patients and therefore enhanced pulsatility the difference from manual evaluation was -2.1 mm Hg (n = 18). In conclusion, adaptation of the classical cuff-pressure method with ultrasound evaluation of peripheral flow allows reliable determination of blood pressure in patients with low pulsatility resulting from implanted rotary cardiac assist pumps. By development of a wristwatch sensor and an automatic control system a robust method for daily use could be developed.

Entities:  

Mesh:

Year:  2004        PMID: 15113339     DOI: 10.1111/j.1525-1594.2004.07095.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

1.  Mechanical circulatory support device-heart hysteretic interaction can predict left ventricular end diastolic pressure.

Authors:  Brian Y Chang; Steven P Keller; Sonya S Bhavsar; Noam Josephy; Elazer R Edelman
Journal:  Sci Transl Med       Date:  2018-02-28       Impact factor: 17.956

Review 2.  Kidney replacement therapy in pediatric patients on mechanical circulatory support: challenges for the pediatric nephrologist.

Authors:  Alexandra Idrovo; Natasha Afonso; Jack Price; Sebastian Tume; Ayse Akcan-Arikan
Journal:  Pediatr Nephrol       Date:  2020-05-28       Impact factor: 3.714

Review 3.  Recent Research and Developing Trends of Wearable Sensors for Detecting Blood Pressure.

Authors:  Toshiya Arakawa
Journal:  Sensors (Basel)       Date:  2018-08-23       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.