Literature DB >> 15111636

The influence of specimen attachment and dimension on microtensile strength.

A A El Zohairy1, A J de Gee, N de Jager, L J van Ruijven, A J Feilzer.   

Abstract

The higher microtensile bond strength values found for specimens with a smaller cross-sectional area are often explained by the lower occurrence of internal defects and surface flaws. We hypothesized that this aberrant behavior is mainly caused by the lateral way of attachment of the specimens to the testing device, which makes the strength dependent on the thickness. This study showed that composite bars of 1x1x10, 1x2x10, and 1x3x10mm attached at their 1-mm-wide side (situation A) fractured at loads of the same magnitude, as a result of which the microtensile strength ( micro TS), calculated as F/A (force at fracture/cross-sectional area), significantly increased for specimens with decreasing thickness. Attachment at the 1-, 2-, or 3-mm-wide side (situation B) resulted in equal micro TS values (P > 0.05). Finite element analysis showed different stress patterns for situation A, but comparable patterns for situation B. Both situations showed the same maximum stress at fracture.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15111636     DOI: 10.1177/154405910408300513

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  5 in total

1.  Effects of polymerization contraction on interface's microTBS of luting material and dentin.

Authors:  Elena Cabrera; José C de la Macorra
Journal:  Clin Oral Investig       Date:  2009-05-30       Impact factor: 3.573

2.  Shear bond strength and fracture analysis of human vs. bovine teeth.

Authors:  Stefan Rüttermann; Anika Braun; Ralf Janda
Journal:  PLoS One       Date:  2013-03-18       Impact factor: 3.240

3.  Immediate and delayed micro-tensile bond strength of different luting resin cements to different regional dentin.

Authors:  Abdelraheem Mohamed Ali; Ibrahim Mohamed Hamouda; Mohamed Hamed Ghazy; Manal Mohamed Abo-Madina
Journal:  J Biomed Res       Date:  2012-12-06

4.  Tensile strength of bilayered ceramics and corresponding glass veneers.

Authors:  Chuchai Anunmana; Tharee Champirat; Bundhit Jirajariyavej
Journal:  J Adv Prosthodont       Date:  2014-06-24       Impact factor: 1.904

5.  Microtensile bond strength of CAD/CAM-fabricated polymer-ceramics to different adhesive resin cements.

Authors:  Leyla Sadighpour; Farideh Geramipanah; Zahra Ghasri; Mehrnoosh Neshatian
Journal:  Restor Dent Endod       Date:  2018-09-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.