Literature DB >> 15111165

A new poly-2-methoxyethylacrylate-coated cardiopulmonary bypass circuit possesses superior platelet preservation and inflammatory suppression efficacy.

Takeshi Ikuta1, Hiromichi Fujii, Toshihiko Shibata, Koji Hattori, Hidekazu Hirai, Hiroshi Kumano, Shigefumi Suehiro.   

Abstract

BACKGROUND: Poly-2-methoxyethylacrylate (PMEA) is a new coating material, and several studies have revealed that PMEA-coated cardiopulmonary bypass (CPB) circuits have good biocompatibility. This study sought to compare this biocompatibility with those of heparin-coated and noncoated circuits.
METHODS: Forty-five patients undergoing coronary artery bypass grafting were randomly assigned to PMEA-coated (group P, n = 15), heparin-coated (group H, n = 15), or noncoated (group N, n = 15) circuit groups. Clinical data and the following markers were analyzed: (1) platelet preservation by number of platelets; (2) complement (C) activation by C3a and C4a levels; (3) inflammatory response by interleukin-6 (IL-6) and interleukin-8 (IL-8) levels.
RESULTS: Platelet numbers were significantly preserved in group P compared with groups N and H. Postoperative blood loss did not differ among the groups. During CPB, C3a values were significantly lower in group H (536 +/- 145 ng/mL) than in group P (1,458 +/- 433 ng/mL, p < 0.01) and group N (1,815 +/- 845 ng/mL, p < 0.01). The C4a values did not differ 60 minutes after CPB initiation among the groups. The IL-6 and IL-8 levels were significantly lower in group P and group H than in group N.
CONCLUSIONS: The PMEA coating was superior to heparin coating and noncoating in preserving platelets, and was equivalent to heparin coating in terms of the perioperative clinical course and inhibition of inflammatory cytokines, but slightly inferior in reducing complement activation.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15111165     DOI: 10.1016/j.athoracsur.2003.10.060

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  12 in total

1.  In vivo comparison study of FDA-approved surface-modifying additives and poly-2-methoxyethylacrylate circuit surfaces coatings during cardiopulmonary bypass.

Authors:  Angela Ask; David Holt; Lynette Smith
Journal:  J Extra Corpor Technol       Date:  2006-03

2.  Evaluation of biocompatible cardiopulmonary bypass circuit use during pediatric open heart surgery.

Authors:  Joseph Deptula; Kimberly Glogowski; Kellie Merrigan; Kim Hanson; Donald Felix; James Hammel; Kim Duncan
Journal:  J Extra Corpor Technol       Date:  2006-03

3.  Miniaturized biocompatible cardiopulmonary bypass for the Fontan procedure.

Authors:  Keiichi Itatani; Kagami Miyaji; Takashi Miyamoto; Nobuyuki Inoue; Takahiro Tomoyasu; Satoshi Kohira; Hajime Sato; Kuniyoshi Ohara
Journal:  Surg Today       Date:  2010-11-03       Impact factor: 2.549

4.  Trends and emerging technologies in extracorporeal life support: results of the 2006 ECLS survey.

Authors:  Alicia N Sievert; Anthony G Shackelford; Mary M McCall
Journal:  J Extra Corpor Technol       Date:  2009-06

5.  Poly-2-methoxyethylacrylate-coated cardiopulmonary bypass circuit can reduce transfusion of platelet products compared to heparin-coated circuit during aortic arch surgery.

Authors:  Katsuhiro Hosoyama; Koki Ito; Shunsuke Kawamoto; Kiichiro Kumagai; Masatoshi Akiyama; Osamu Adachi; Satoshi Kawatsu; Konosuke Sasaki; Marina Suzuki; Yumi Sugawara; Yuya Shimizu; Yoshikatsu Saiki
Journal:  J Artif Organs       Date:  2016-02-24       Impact factor: 1.731

6.  Long-term survival and functional recovery after isolated coronary artery bypass grafting in patients with severe left ventricular dysfunction.

Authors:  Toshihiro Fukui; Toshihiko Shibata; Yasuyuki Sasaki; Hidekazu Hirai; Manabu Motoki; Yosuke Takahashi; Atsushi Nakahira; Shigefumi Suehiro
Journal:  Gen Thorac Cardiovasc Surg       Date:  2007-10

7.  Poly-2-methoxyethylacrylate-coated bypass circuits reduce activation of coagulation system and inflammatory response in congenital cardiac surgery.

Authors:  Yasuyuki Suzuki; Kazuyuki Daitoku; Masahito Minakawa; Kozo Fukui; Ikuo Fukuda
Journal:  J Artif Organs       Date:  2008-10-05       Impact factor: 1.731

8.  Long-term experience with the Sorin Bicarbon and Edwards Mira mechanical valve prostheses in the mitral position.

Authors:  Toshihiro Fukui; Toshihiko Shibata; Yasuyuki Sasaki; Hidekazu Hirai; Manabu Motoki; Yosuke Takahashi; Shigefumi Suehiro
Journal:  Gen Thorac Cardiovasc Surg       Date:  2007-03

Review 9.  Novel Surfaces in Extracorporeal Membrane Oxygenation Circuits.

Authors:  Andrea Ontaneda; Gail M Annich
Journal:  Front Med (Lausanne)       Date:  2018-11-20

Review 10.  Hematologic concerns in extracorporeal membrane oxygenation.

Authors:  Jonathan Sniderman; Paul Monagle; Gail M Annich; Graeme MacLaren
Journal:  Res Pract Thromb Haemost       Date:  2020-05-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.