Bicarbonate- versus lactate-based CAPD fluids: a biocompatibility study in rabbits.

H T Schambye1, P Flesner, R B Pedersen, M Hardt-Madsen, J Chemnitz, H K Christensen, A Detmer, F B Pedersen.   

Abstract

Previous in vitro biocompatibility studies have shown bicarbonate-based continuous ambulatory peritoneal dialysis (CAPD) fluids to be superior to those based upon lactate/acetate. To evaluate these findings in vivo, 41 rabbits were subjected to CAPD for four weeks in a randomized prospective study using either Dianeal, a commercially available dialysis fluid containing lactate, or 87b, a bicarbonate-based CAPD fluid. Ten rabbits with CAPD catheters, which were flushed with a heparin solution every 36 hours, served as controls. None of the control rabbits showed clinical or histopathological signs of peritonitis, while 8 of 20 in the Dianeal group and 6 of 21 in the 87b group contracted peritonitis. Four rabbits in the Dianeal group had to be sacrificed early due to severe peritonitis. Post mortem examinations, including scanning and light microscopy, did not reveal any macroscopic or microscopic differences among the three groups of noninfected animals. No significant distinctions between the groups could be made for body temperature, weight gain, dialysate volume, dialysate differential leukocyte count, dialysate protein content, and food intake during the course of the study. In conclusion, the present animal model did not reveal any major difference in the biocompatibility between the lactate- and the bicarbonate-based CAPD fluids.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1511044

Source DB:  PubMed          Journal:  Perit Dial Int        ISSN: 0896-8608            Impact factor:   1.756


  5 in total

1.  Biocompatibility of a new PD solution for Japan, Reguneal™, measured as in vitro proliferation of fibroblasts.

Authors:  Bart Dioos; Goedele Paternot; Rose-Marie Jenvert; Annick Duponchelle; Mark R Marshall; Migaku Nakajima; Edward Ramirez Ganoza; James A Sloand; Anders P Wieslander
Journal:  Clin Exp Nephrol       Date:  2018-06-20       Impact factor: 2.801

Review 2.  Peritoneal changes in patients on long-term peritoneal dialysis.

Authors:  Raymond T Krediet; Dirk G Struijk
Journal:  Nat Rev Nephrol       Date:  2013-05-14       Impact factor: 28.314

3.  Surgical Techniques for Catheter Placement and 5/6 Nephrectomy in Murine Models of Peritoneal Dialysis.

Authors:  Guadalupe Tirma González-Mateo; Lucía Pascual-Antón; Pilar Sandoval; Abelardo Aguilera Peralta; Manuel López-Cabrera
Journal:  J Vis Exp       Date:  2018-07-19       Impact factor: 1.355

4.  Conventional versus biocompatible peritoneal dialysis fluids: more questions than answers?

Authors:  Karima Farhat; Frans Jan van Ittersum; Piet Marten Ter Wee; Caroline Ellen Douma
Journal:  NDT Plus       Date:  2008-10

Review 5.  Animal Models of Peritoneal Dialysis: Thirty Years of Our Own Experience.

Authors:  Krzysztof Pawlaczyk; Ewa Baum; Krzysztof Schwermer; Krzysztof Hoppe; Bengt Lindholm; Andrzej Breborowicz
Journal:  Biomed Res Int       Date:  2015-07-06       Impact factor: 3.411

  5 in total