Literature DB >> 15108781

Predictors of failure to cure atrial fibrillation with the mini-maze operation.

Zoltan A Szalay1, Wojtek Skwara, Wolf Peter Klövekorn, Hans-Peter Brunner-La Rocca, Igor Knez, Kirk Graves, Paul R Vogt, Erwin P Bauer.   

Abstract

BACKGROUND: Maze-III is a complex surgical procedure designed to treat chronic atrial fibrillation. A reduction in the number of right and left atrial incisions could decrease the operative time. The aim of this study was to assess the results of a mini-maze operation and to define predictors of its failure.
METHODS: Between 1995 and 2000, 72 patients (mean age 64 +/- 9 years) undergoing cardiac surgery had a concomitant mini-maze operation for symptomatic chronic atrial fibrillation. Three and 12 months post-operatively, heart rhythm and left atrial transport functions were assessed by electrophysiology, echocardiography, and magnetic resonance imaging. Multivariate analysis was performed to identify predictors of failure of the mini-maze operation.
RESULTS: Operative mortality was 1.4% (1/72). Death during follow-up occurred in 5.6% of patients (4/71), in one due to chronic heart failure. After 1 year, 80% of patients (48/60) were either in sinus rhythm (n = 43; 72%) or had a pacemaker (n = 5; 8%) implanted due to sick sinus syndrome. Intermittent and chronic atrial fibrillation was found in 20% of patients (12/60). Preoperative duration of atrial fibrillation (p = 0.05), preoperative left atrial diameter (p = 0.001), preoperative right atrial diameter (p = 0.02), a reduced left ventricular ejection fraction (p = 0.03), an increased left ventricular end-diastolic diameter (p = 0.04), and the presence of mitral valve stenosis (p = 0.001) were found to be univariate predictors of failure of the mini-maze operation 1 year postoperatively. Multivariate analysis defined preoperative diagnosis of mitral valve stenosis (p = 0.005; OR 117.5), longer duration of preoperative atrial fibrillation (p = 0.01; OR 1.33), and increased preoperative left ventricular end-systolic diameter (p = 0.02; OR 1.2) as incremental independent risk factors for failure of the mini-maze operation to cure chronic atrial fibrillation.
CONCLUSION: The mini-maze operation is a safe procedure with similar results to that of Cox's Maze-III operation. The less-invasive mini-maze operation could be applicable even to patients with severely reduced left ventricular function, in whom complex cardiac surgery has to be performed concomitantly as well as in those presenting severe comorbidities.

Entities:  

Mesh:

Year:  2004        PMID: 15108781     DOI: 10.1111/j.0886-0440.2004.04001.x

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  2 in total

1.  Modified Maze Procedure for Atrial Fibrillation as an Adjunct to Elective Cardiac Surgery: Predictors of Mid-Term Recurrence and Echocardiographic Follow-Up.

Authors:  Claudia Loardi; Francesco Alamanni; Fabrizio Veglia; Claudia Galli; Alessandro Parolari; Marco Zanobini
Journal:  Tex Heart Inst J       Date:  2015-08-01

2.  Development Of A Novel Scoring System That Determines The Success Of Atrial Fibrillation Ablation As Part Of Cardiac Surgery.

Authors:  Norton A; D Schlosshan; I Ahmed; M H Tayebjee
Journal:  J Atr Fibrillation       Date:  2015-10-31
  2 in total