Literature DB >> 15108030

Hyperpolarized 3He lung ventilation imaging with B1-inhomogeneity correction in a single breath-hold scan.

G W Miller1, T A Altes, J R Brookeman, E E De Lange, J P Mugler.   

Abstract

The signal-to-noise ratio (SNR) of hyperpolarized noble gas MR images is sensitive to the flip angle used. Variations in flip angle due to B1-inhomogeneity of the RF coil cause intensity variation artifacts in lung ventilation images which may mask or mimic disease. We show these artifacts can be minimized by using the optimal flip angle and corrected if the local flip angle is known. Hyperpolarized 3He lung images were obtained in ten healthy subjects using both a conventional gradient-echo sequence and a new hybrid pulse sequence designed to simultaneously acquire lung ventilation images and corresponding flip-angle maps in comparable imaging time. Flip-angle maps and corrected images were calculated from the hybrid scan and compared with conventional images. The qualitative theoretical dependence of flip angle on SNR was verified. Ventilation images and flip-angle maps were successfully obtained with the hybrid sequence. Corrections to image intensity calculated from the flip-angle maps appeared reasonable for images acquired using an average flip angle near optimal. Use of the optimal flip angle is crucial to the quality of lung ventilation images. Artifactual intensity variations due to RF-coil inhomogeneity may be identified and potentially corrected using our hybrid sequence. Copyright 2004 ESMRMB

Mesh:

Substances:

Year:  2004        PMID: 15108030     DOI: 10.1007/s10334-003-0028-2

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  22 in total

1.  3D hyperpolarized He-3 MRI of ventilation using a multi-echo projection acquisition.

Authors:  James H Holmes; Rafael L O'Halloran; Ethan K Brodsky; Youngkyoo Jung; Walter F Block; Sean B Fain
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

2.  Assessment of MR imaging during one-lung flooding in a large animal model.

Authors:  Frank Wolfram; Daniel Güllmar; Joachim Böttcher; Harald Schubert; Sabine Bischoff; Jürgen R Reichenbach; Thomas Günther Lesser
Journal:  MAGMA       Date:  2019-06-01       Impact factor: 2.310

3.  Feasibility, tolerability and safety of pediatric hyperpolarized 129Xe magnetic resonance imaging in healthy volunteers and children with cystic fibrosis.

Authors:  Laura L Walkup; Robert P Thomen; Teckla G Akinyi; Erin Watters; Kai Ruppert; John P Clancy; Jason C Woods; Zackary I Cleveland
Journal:  Pediatr Radiol       Date:  2016-08-05

4.  Mapping and correcting hyperpolarized magnetization decay with radial keyhole imaging.

Authors:  Peter J Niedbalski; Matthew M Willmering; Scott H Robertson; Matthew S Freeman; Wolfgang Loew; Randy O Giaquinto; Christopher Ireland; Ronald G Pratt; Charles L Dumoulin; Jason C Woods; Zackary I Cleveland
Journal:  Magn Reson Med       Date:  2019-03-07       Impact factor: 4.668

5.  Ventilation/Perfusion Relationships and Gas Exchange: Measurement Approaches.

Authors:  Susan R Hopkins
Journal:  Compr Physiol       Date:  2020-07-08       Impact factor: 9.090

6.  N4ITK: improved N3 bias correction.

Authors:  Nicholas J Tustison; Brian B Avants; Philip A Cook; Yuanjie Zheng; Alexander Egan; Paul A Yushkevich; James C Gee
Journal:  IEEE Trans Med Imaging       Date:  2010-04-08       Impact factor: 10.048

7.  Quantitative analysis of hyperpolarized 129Xe ventilation imaging in healthy volunteers and subjects with chronic obstructive pulmonary disease.

Authors:  Rohan S Virgincar; Zackary I Cleveland; S Sivaram Kaushik; Matthew S Freeman; John Nouls; Gary P Cofer; Santiago Martinez-Jimenez; Mu He; Monica Kraft; Jan Wolber; H Page McAdams; Bastiaan Driehuys
Journal:  NMR Biomed       Date:  2012-10-13       Impact factor: 4.044

Review 8.  Hyperpolarized 129Xe MRI of the human lung.

Authors:  John P Mugler; Talissa A Altes
Journal:  J Magn Reson Imaging       Date:  2013-02       Impact factor: 4.813

9.  Calibration of RF transmitter voltages for hyperpolarized gas MRI.

Authors:  Adil Bashir; Mark S Conradi; Jason C Woods; James D Quirk; Ddmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2009-01       Impact factor: 4.668

10.  Evaluation of structure-function relationships in asthma using multidetector CT and hyperpolarized He-3 MRI.

Authors:  Sean B Fain; Guillermo Gonzalez-Fernandez; Eric T Peterson; Michael D Evans; Ronald L Sorkness; Nizar N Jarjour; William W Busse; Janet E Kuhlman
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.