Literature DB >> 15105229

Tracheal ring fracture during a PercuTwist tracheostomy procedure.

Emmanuel Scherrer1, Loic Tual, Gilles Dhonneur.   

Abstract

UNLABELLED: Because of difficult weaning from mechanical ventilation, a 59-yr-old man admitted for emergency cardiac surgery underwent a bedside PercuTwist tracheostomy on day 14 of his intensive care unit stay. We observed a double fracture of the second tracheal ring during the initial dilation process with the PercuTwist dilator, associated with distal migration of a cartilage fragment, which was avulsed from the anterior portion of the second cartilaginous ring. IMPLICATIONS: Like other antegrade single-step techniques, the PercuTwist tracheostomy presents the risk of anterior tracheal wall damage during the initial stage of the dilation process. Antegrade forces applied to the trachea should be minimized by sufficiently deep skin incision and both slow and smooth initial rotation of the dilator.

Entities:  

Mesh:

Year:  2004        PMID: 15105229     DOI: 10.1213/01.ane.0000111112.96668.58

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  2 in total

1.  A comparative study of complications and long term outcomes of Surgical Tracheostomy and two techniques of Percutaneous Tracheostomy.

Authors:  S Kiran; S Eapen; Vivek Chopra
Journal:  Indian J Crit Care Med       Date:  2015-02

2.  Thermoforming of tracheal cartilage: viability, shape change, and mechanical behavior.

Authors:  Yongseok Chae; Dmitriy Protsenko; Paul K Holden; Cara Chlebicki; Brian J F Wong
Journal:  Lasers Surg Med       Date:  2008-10       Impact factor: 4.025

  2 in total