Literature DB >> 15104787

Wall relative humidity: a simple and reliable index for predicting Stachybotrys chartarum infestation in dwellings.

S Boutin-Forzano1, C Charpin-Kadouch, S Chabbi, N Bennedjai, H Dumon, D Charpin.   

Abstract

UNLABELLED: Because the indoor mold Stachybotrys chartarum has been considered as potentially responsible for serious health effects, its identification in dwellings with water damages is of utmost importance. As such dwellings are many, it would be of great value to have a simple and reliable index for predicting its presence. The aim of the study was to compare measurements of wall relative humidity (RH) to mold identification in 458 samples from 100 dwellings. Mold identification was performed by direct microscopic examination of a sample collected on the wall by the gummed paper technique. Mean (+/- s.d.) wall RH (%) was much higher (97.0 +/- 6.1) on the 30 samples where S. chartarum was identified compared with the 291 samples where other molds were identified (41.8 +/- 36.9) and to the 137 samples where no molds were identified (38.9 +/- 34.8). There was no straightforward relationship between wall and room RH. In conclusion, this study clearly demonstrate that the simple measurement of wall RH can be used as a reliable index for discarding and suspecting S. chartarum infestation in dwellings. PRACTICAL IMPLICATIONS: This paper suggests that very high relative humidity (RH) within walls is a strong risk factor for their infestation with the 'toxic mold' Stachybotrys chartarum. Besides, data from the literature demonstrate that other molds are able to produce mycotoxins when RH is very high. Thus, measurement of wall RH, which is easy to perform and very cheap, could be used as a screening tool to select those dwellings where mold identification should be performed and remediation should be promptly carried out.

Entities:  

Mesh:

Year:  2004        PMID: 15104787     DOI: 10.1111/j.1600-0668.2004.00233.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  4 in total

1.  Cultivation and aerosolization of Stachybotrys chartarum for modeling pulmonary inhalation exposure.

Authors:  Angela R Lemons; Tara L Croston; W Travis Goldsmith; Mark A Barnes; Mukhtar A Jaderson; Ju-Hyeong Park; Walter McKinney; Donald H Beezhold; Brett J Green
Journal:  Inhal Toxicol       Date:  2019-12-24       Impact factor: 2.724

2.  The influence of water activity and temperature on germination, growth and sporulation of Stachybotrys chartarum strains.

Authors:  Schale Frazer; Naresh Magan; David Aldred
Journal:  Mycopathologia       Date:  2011-02-24       Impact factor: 2.574

3.  Inhalation of Stachybotrys chartarum Fragments Induces Pulmonary Arterial Remodeling.

Authors:  Tara L Croston; Angela R Lemons; Mark A Barnes; William T Goldsmith; Marlene S Orandle; Ajay P Nayak; Dori R Germolec; Brett J Green; Donald H Beezhold
Journal:  Am J Respir Cell Mol Biol       Date:  2020-05       Impact factor: 6.914

Review 4.  Mechanisms of mycotoxin-induced neurotoxicity through oxidative stress-associated pathways.

Authors:  Kunio Doi; Koji Uetsuka
Journal:  Int J Mol Sci       Date:  2011-08-15       Impact factor: 5.923

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.