Literature DB >> 15104314

MAX meets ADAM: a dosimetric comparison between a voxel-based and a mathematical model for external exposure to photons.

R Kramer1, J W Vieira, H J Khoury, F de Andrade Lima.   

Abstract

The International Commission on Radiological Protection intends to revise the organ and tissue equivalent dose conversion coefficients published in various reports. For this purpose the mathematical human medical internal radiation dose (MIRD) phantoms, actually in use, have to be replaced by recently developed voxel-based phantoms. This study investigates the dosimetric consequences, especially with respect to the effective male dose, if not only a MIRD phantom is replaced by a voxel phantom, but also if the tissue compositions and the radiation transport codes are changed. This task will be resolved by systematically replacing in the mathematical ADAM/GSF exposure model, first the radiation transport code, then the tissue composition and finally the phantom anatomy, in order to arrive at the voxel-based MAX/EGS4 exposure model. The results show that the combined effect of these replacements can decrease the effective male dose by up to 25% for external exposures to photons for incident energies above 30 keV for different field geometries, mainly because of increased shielding by a heterogeneous skeleton and by the overlying adipose and muscle tissue, and also because of the positions internal organs have in a realistically designed human body compared to their positions in the mathematically constructed phantom.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15104314     DOI: 10.1088/0031-9155/49/6/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Advances in Computational Human Phantoms and Their Applications in Biomedical Engineering - A Topical Review.

Authors:  Wolfgang Kainz; Esra Neufeld; Wesley E Bolch; Christian G Graff; Chan Hyeong Kim; Niels Kuster; Bryn Lloyd; Tina Morrison; Paul Segars; Yeon Soo Yeom; Maria Zankl; X George Xu; Benjamin M W Tsui
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-01

2.  A comparison of pediatric and adult CT organ dose estimation methods.

Authors:  Yiming Gao; Brian Quinn; Usman Mahmood; Daniel Long; Yusuf Erdi; Jean St Germain; Neeta Pandit-Taskar; X George Xu; Wesley E Bolch; Lawrence T Dauer
Journal:  BMC Med Imaging       Date:  2017-04-26       Impact factor: 1.930

3.  Effective dose in medicine.

Authors:  C J Martin
Journal:  Ann ICRP       Date:  2020-11-04
  3 in total