Literature DB >> 15100786

Design and simulation of the micromixer with chaotic advection in twisted microchannels.

Chun-Ping Jen1, Chung-Yi Wu, Yu-Cheng Lin, Ching-Yi Wu.   

Abstract

Chaotic mixers with twisted microchannels were designed and simulated numerically in the present study. The phenomenon whereby a simple Eulerian velocity field may generate a chaotic response in the distribution of a Lagrangian marker is termed chaotic advection. Dynamic system theory indicates that chaotic particle motion can occur when a velocity field is either two-dimensional and time-dependent, or three-dimensional. In the present study, micromixers with three-dimensional structures of the twisted microchannel were designed in order to induce chaotic mixing. In addition to the basic T-mixer, three types of micromixers with inclined, oblique and wavelike microchannels were investigated. In the design of each twisted microchannel, the angle of the channels' bottoms alternates in each subsection. When the fluids enter the twisted microchannels, the flow sways around the varying structures within the microchannels. The designs of the twisted microchannels provide a third degree of freedom to the flow field in the microchannel. Therefore, chaotic regimes that lead to chaotic mixing may arise. The numerical results indicate that mixing occurs in the main channel and progressively larger mixing lengths are required as the Peclet number increased. The swaying of the flow in the twisted microchannel causes chaotic advection. Among the four micromixer designs, the micromixer with the inclined channel most improved mixing. Furthermore, using the inclined mixer with six subsections yielded optimum performance, decreasing the mixing length by up to 31% from that of the basic T-mixer.

Mesh:

Substances:

Year:  2003        PMID: 15100786     DOI: 10.1039/b211091a

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  7 in total

1.  Computerized microfluidic cell culture using elastomeric channels and Braille displays.

Authors:  Wei Gu; Xiaoyue Zhu; Nobuyuki Futai; Brenda S Cho; Shuichi Takayama
Journal:  Proc Natl Acad Sci U S A       Date:  2004-10-28       Impact factor: 11.205

2.  Continuous flow microreactor for protein PEGylation.

Authors:  P Madadkar; P R Selvaganapathy; R Ghosh
Journal:  Biomicrofluidics       Date:  2018-08-20       Impact factor: 2.800

3.  Concentration and purification of human immunodeficiency virus type 1 virions by microfluidic separation of superparamagnetic nanoparticles.

Authors:  Grace D Chen; Catharina J Alberts; William Rodriguez; Mehmet Toner
Journal:  Anal Chem       Date:  2010-01-15       Impact factor: 6.986

4.  Microfluidic mixing: a review.

Authors:  Chia-Yen Lee; Chin-Lung Chang; Yao-Nan Wang; Lung-Ming Fu
Journal:  Int J Mol Sci       Date:  2011-05-18       Impact factor: 5.923

5.  Microfluidic circulating reactor system for sensitive and automated duplex-specific nuclease-mediated microRNA detection.

Authors:  Xin Zhou; Hongmei Cao; Yong Zeng
Journal:  Talanta       Date:  2021-04-20       Impact factor: 6.556

Review 6.  Microfluidic devices: useful tools for bioprocess intensification.

Authors:  Marco P C Marques; Pedro Fernandes
Journal:  Molecules       Date:  2011-09-30       Impact factor: 4.411

7.  A millisecond passive micromixer with low flow rate, low sample consumption and easy fabrication.

Authors:  Yuanyuan Liao; Yves Mechulam; Benedikt Lassalle-Kaiser
Journal:  Sci Rep       Date:  2021-10-11       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.