Literature DB >> 15096442

Cardiovascular changes with the laryngeal mask airway in cardiac anaesthesia.

S R Bennett1, D Grace, S C Griffin.   

Abstract

BACKGROUND: The laryngeal mask airway (LMA) causes fewer haemodynamic changes, particularly in mean arterial pressure (MAP) and heart rate (HR), than tracheal intubation using either laryngoscopy or the intubating LMA. There are no data for patients with coronary artery disease.
METHOD: We studied 27 patients having coronary artery bypass grafting, prospectively randomized to be managed with either the LMA or tracheal intubation using either laryngoscopy or the ILMA. We used invasive monitoring to compare the haemodynamic effects in each group during induction and emergence from anaesthesia.
RESULTS: Both methods of intubation caused an increase in MAP compared with the LMA (P<0.05). Mixed venous oxygen saturation increased in the intubated patients but not with the LMA (P<0.05). HR did not change at induction in the LMA group. Changes at extubation were similar in all groups but cardiac index was lower in the LMA group (P<0.05).
CONCLUSION: The LMA allows airway management without hypertension and tachycardia and should be considered when anaesthetizing patients with coronary disease.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15096442     DOI: 10.1093/bja/aeh149

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  4 in total

1.  Haemodynamic response to endotracheal intubation in coronary artery disease: Direct versus video laryngoscopy.

Authors:  Muralidhar Kanchi; Hema C Nair; Sanjay Banakal; Keshava Murthy; C Murugesan
Journal:  Indian J Anaesth       Date:  2011-05

2.  Better Hemodynamic Profile of Laryngeal Mask Airway Insertion Compared to Laryngoscopy and Tracheal Intubation.

Authors:  Hashem Jarineshin; Saeed Kashani; Majid Vatankhah; Alireza Abdulahzade Baghaee; Sahar Sattari; Fereydoon Fekrat
Journal:  Iran Red Crescent Med J       Date:  2015-08-12       Impact factor: 0.611

3.  ProSeal laryngeal mask airway as an alternative to standard endotracheal tube in securing upper airway in the patients undergoing beating-heart coronary artery bypass grafting.

Authors:  Kalpana Shah
Journal:  Ann Card Anaesth       Date:  2017 Jan-Mar

4.  Laryngeal mask for airway management in open tracheal surgery-a retrospective analysis of 54 cases.

Authors:  Martina Krecmerova; Jan Schutzner; Pavel Michalek; Paul Johnson; Tomas Vymazal
Journal:  J Thorac Dis       Date:  2018-05       Impact factor: 2.895

  4 in total