Literature DB >> 15095051

Interaction between cardiac beat-to-beat interval changes and systolic blood pressure changes.

Emma J Bowers1, Alan Murray.   

Abstract

This study assessed the interaction between cardiac beat-to-beat interval changes and systolic pressure (SP) changes. Twenty subjects breathed regularly following displayed breathing signals at 4, 6, 8, 10, 12 and 14 breaths per minute, each for 5 minutes. ECG, non-invasive blood pressure (Finapres) and respiration waveforms were recorded. Time offsets between the cyclic patterns of RR-interval and SP changes were calculated. Displayed breathing signals were well followed; the mean correlation between displayed and recorded breathing signals ranged from 0.72 to 0.86. The time offset between RR-interval peaks and subsequent SP troughs decreased with increasing respiration rate, 3.8 +/- 1.7 s, 3.5 +/- 0.7 s, 3.1 +/- 0.6 s, 2.6 +/- 0.4 s, 2.3 +/- 0.4 s and 2.0 +/- 0.4 s mean +/- SD at 4, 6, 8, 10, 12 and 14 breaths per minute respectively. The relationship between mean time offset and frequency was significant (p < 0.001), with a 95% prediction interval of +/- 0.24 s. Published data showed no relationship between time offset and frequency, with a 95% prediction interval of +/- 2.8 s. However, when the offset definition proposed in this research was applied to these data, a significant relationship (p < 0.01) was evident, with a 95% prediction interval of +/- 1.5 s. In conclusion, apparently contradictory previous findings achieve good consensus when a standardized method for presenting results is applied. A delay exists between RR-interval and blood pressure changes, and this delay varies with breathing frequency.

Mesh:

Year:  2004        PMID: 15095051     DOI: 10.1007/s10286-004-0169-z

Source DB:  PubMed          Journal:  Clin Auton Res        ISSN: 0959-9851            Impact factor:   4.435


  3 in total

1.  Delayed effect of blood pressure fluctuations on heart rate in patients with end-stage kidney disease.

Authors:  Dan Sapoznikov; Dvora Rubinger
Journal:  Med Biol Eng Comput       Date:  2011-07-14       Impact factor: 2.602

2.  Autonomic nervous system function following prenatal opiate exposure.

Authors:  Matthew Todd Hambleton; Eric W Reynolds; Thitinart Sithisarn; Stuart J Traxel; Abhijit R Patwardhan; Timothy N Crawford; Marta S Mendiondo; Henrietta S Bada
Journal:  Front Pediatr       Date:  2013-10-17       Impact factor: 3.418

3.  Effect of respiration on Korotkoff sounds and oscillometric cuff pressure pulses during blood pressure measurement.

Authors:  Dingchang Zheng; Luigi Yuri Di Marco; Alan Murray
Journal:  Med Biol Eng Comput       Date:  2014-03-26       Impact factor: 2.602

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.