Literature DB >> 15093225

Comparisons of platinum, gold, palladium and glassy carbon as electrode materials in the design of biosensors for glutamate.

Robert D O'Neill1, Seung-Cheol Chang, John P Lowry, Calum J McNeil.   

Abstract

Four electrode materials: Pt, Au, Pd and glassy carbon (GC), were studied to investigate their suitability as substrates in the development of two different classes of glutamate biosensor. Glutamate oxidase cross-linked onto poly(o-phenylenediamine) was chosen as the type 1 biosensor (PPD/GluOx), incorporating PPD as the permselective element to detect H(2)O(2) directly on the electrode surface at relatively high applied potentials. GluOx and horseradish peroxidase/redox polymer modified electrodes (Os(2+)PVP/HRP/GluOx) that relied on enzyme-catalysed H(2)O(2) detection at lower applied potentials were used as type 2 biosensors. The voltammetric and amperometric responses to the enzyme signal transduction molecule, H(2)O(2), and the archetypal interference species in biological applications, ascorbic acid, were determined on the bare and PPD/GluOx-modified surfaces. The amperometric responses of these electrodes were stable over several days of continuous recording in phosphate buffered saline (pH 7.4). The sensitivity of the type 1 biosensors to H(2)O(2) and glutamate showed parallel trends with low limits of detection and good linearity at low concentrations: Pt>Au approximately Pd>>GC. Type 2 biosensors out-performed the type 1 design for all electrode substrates, except Pt. However, the presence of the permselective PPD membrane in the type 1 biosensors, not feasible in the type 2 design, suggests that Pt/PPD/GluOx might have the best all-round characteristics for glutamate detection in biological media containing interference species such as ascorbic acid. Other points affecting a final choice of substrate should include factors such as mass production issues.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15093225     DOI: 10.1016/j.bios.2003.12.004

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  15 in total

1.  Ceramic-based microelectrode arrays: recording surface characteristics and topographical analysis.

Authors:  Pooja M Talauliker; David A Price; Jason J Burmeister; Silpa Nagari; Jorge E Quintero; Francois Pomerleau; Peter Huettl; J Todd Hastings; Greg A Gerhardt
Journal:  J Neurosci Methods       Date:  2011-04-12       Impact factor: 2.390

Review 2.  A Comprehensive Review: Development of Electrochemical Biosensors for Detection of Cyanotoxins in Freshwater.

Authors:  Vasileia Vogiazi; Armah de la Cruz; Siddharth Mishra; Vesselin Shanov; William R Heineman; Dionysios D Dionysiou
Journal:  ACS Sens       Date:  2019-05-14       Impact factor: 7.711

3.  In vivo Electrochemical Biosensor for Brain Glutamate Detection: A Mini Review.

Authors:  Siti Kartika Hamdan; Ainiharyati Mohd Zain
Journal:  Malays J Med Sci       Date:  2014-12

4.  Fabrication of Highly Sensitive Pt-black Electrochemical Sensors for GABA Detection.

Authors:  Sung Sik Chu; Paul Marsh; Hung A Nguyen; Carolyn E Jones; Miranda M Lim; Hung Cao
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2021-11

5.  Glutamate oxidase biosensor based on mixed ceria and titania nanoparticles for the detection of glutamate in hypoxic environments.

Authors:  Rıfat Emrah Özel; Cristina Ispas; Mallikarjunarao Ganesana; J C Leiter; Silvana Andreescu
Journal:  Biosens Bioelectron       Date:  2013-09-11       Impact factor: 10.618

Review 6.  Review of recent advances in analytical techniques for the determination of neurotransmitters.

Authors:  Maura Perry; Qiang Li; Robert T Kennedy
Journal:  Anal Chim Acta       Date:  2009-09-01       Impact factor: 6.558

7.  Implantable Microprobe with Arrayed Microsensors for Combined Amperometric Monitoring of the Neurotransmitters, Glutamate and Dopamine.

Authors:  Tina T-C Tseng; Harold G Monbouquette
Journal:  J Electroanal Chem (Lausanne)       Date:  2012-07-25       Impact factor: 4.464

8.  Phasic oxygen dynamics confounds fast choline-sensitive biosensor signals in the brain of behaving rodents.

Authors:  Ricardo M Santos; Anton Sirota
Journal:  Elife       Date:  2021-02-15       Impact factor: 8.140

Review 9.  Microsensors for in vivo Measurement of Glutamate in Brain Tissue.

Authors:  Si Qin; Miranda Van der Zeyden; Weite H Oldenziel; Thomas I F H Cremers; Ben H C Westerink
Journal:  Sensors (Basel)       Date:  2008-11-04       Impact factor: 3.576

Review 10.  Fully integrated biochip platforms for advanced healthcare.

Authors:  Sandro Carrara; Sara Ghoreishizadeh; Jacopo Olivo; Irene Taurino; Camilla Baj-Rossi; Andrea Cavallini; Maaike Op de Beeck; Catherine Dehollain; Wayne Burleson; Francis Gabriel Moussy; Anthony Guiseppi-Elie; Giovanni De Micheli
Journal:  Sensors (Basel)       Date:  2012-08-08       Impact factor: 3.576

View more