Accuracy of delayed (24 hours) processing of bronchoalveolar lavage for diagnosing bacterial pneumonia.

Arnaud de Lassence1, Marie-Laure Joly-Guillou, Amar Salah, Laurent Martin-Lefevre, Nadia Hidri, Jean-Damien Ricard, Diane Bouvry, Nathalie de Castro, Didier Dreyfuss.   

Abstract

OBJECTIVE: Pneumonia in the intensive care unit is associated with a high mortality rate. Diagnostic accuracy is mandatory to improve prognosis. However, in many hospitals, samples from the respiratory tract cannot be immediately processed bacteriologically around the clock. This may complicate therapeutic choice based on invasive diagnostic procedures. We evaluated the effect of storing bronchoalveolar lavage fluid at 4 degrees C for 24 hrs on direct examination and culturing for diagnosing pneumonia.
DESIGN: Prospective, paired comparison study.
SETTING: Intensive care unit in a university hospital. PATIENTS: A total of 93 bronchoalveolar lavages were performed on 66 intensive care unit patients who were suspected to have bacterial pneumonia. INTERVENTION: Each sample was divided into two; one half was processed immediately (H0), and the other was processed after refrigeration at 4 degrees C for 24 hrs (H24).
MEASUREMENTS AND MAIN RESULTS: All negative H0 culture samples (n = 31) were also negative for pathogens in H24 samples. Sixty two bronchoalveolar lavage cultures yielded one or more microorganisms, giving a total of 113 microorganisms in one or both samples. The results of positive cultures at H0 and H24 for the culturing diagnostic threshold of 10 colony forming units/mL agreed well (Kappa coefficient, 0.84); agreement was even better (Kappa coefficient, 0.85) when possible contaminants were excluded. The bias calculated as the mean difference between paired culture results was 0.195 +/- 1.31 (Delta log). When considering the accepted threshold of 10 colony forming units/mL, specificity at H24 compared to H0 was excellent (100%), but sensitivity was slightly lower (80%).
CONCLUSION: Delayed processing of bronchoalveolar lavage sampling is an acceptable alternative when immediate culturing cannot be performed because it enables antibiotic administration.

Entities:  

Mesh:

Year:  2004        PMID: 15090947     DOI: 10.1097/01.ccm.0000114813.85853.ea

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  4 in total

1.  Bronchoalveolar lavage for VAP diagnosis: patients must be sampled before any change of antimicrobial therapy.

Authors:  Jean-François Timsit
Journal:  Intensive Care Med       Date:  2007-08-03       Impact factor: 17.440

Review 2.  Use of rapid diagnostic techniques in ICU patients with infections.

Authors:  Almudena Burillo; Emilio Bouza
Journal:  BMC Infect Dis       Date:  2014-11-28       Impact factor: 3.090

Review 3.  Update on ventilator-associated pneumonia.

Authors:  Jean-Francois Timsit; Wafa Esaied; Mathilde Neuville; Lila Bouadma; Bruno Mourvllier
Journal:  F1000Res       Date:  2017-11-29

4.  Storage of bronchoalveolar lavage fluid and accuracy of microbiologic diagnostics in the ICU: a prospective observational study.

Authors:  Nikolaus Kneidinger; Joanna Warszawska; Peter Schenk; Valentin Fuhrmann; Andja Bojic; Alexander Hirschl; Harald Herkner; Christian Madl; Athanasios Makristathis
Journal:  Crit Care       Date:  2013-07-11       Impact factor: 9.097

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.