Literature DB >> 15088739

Determination of fuel dialkyl ethers and BTEX in water using headspace solid-phase microextraction and gas chromatography-flame ionization detection.

Idoia Arambarri1, Maitena Lasa, Rosa Garcia, Esmeralda Millán.   

Abstract

A simple procedure for the determination of methyl tert-butyl ether (MTBE), ethyl tert-butyl ether (ETBE), ethyl butyl ether (EBE), tert-amyl methyl ether (TAME), benzene, toluene, ethylbenzene, and xylenes (BTEX) in water using headspace (HS) solid-phase microextraction (HS-SPME) was developed. The analysis was carried out by gas chromatography (GC) equipped with flame ionization detector (FID) and 100% dimethylpolysiloxane fused capillary column. A 2 Plackett-Burman design for screening and a central composite design (CCD) for optimizing the significant variables were applied. Fiber type, extraction temperature, sodium chloride concentration, and headspace volume were the significant variables. A 65 microm poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB) SPME fiber, 10 degrees C, 300 g/l, and 20 ml of headspace (in 40 ml vial) were respectively chosen for the best extraction response. An extraction time of 10 min was enough to extract the ethers and BTEX. The relative standard deviation (R.S.D.) for the procedure varied from 2.6 (benzene) to 8.5% (ethylbenzene). The method detection limits (MDLs) found were from 0.02 (toluene, ethylbenzene, and xylenes) to 1.1 microg/l (MTBE). The optimized method was applied to the analysis of the rivers, marinas and fishing harbors surface waters from Gipuzkoa (North Spain). Three sampling were done in 1 year from June 2002 to June 2003. Toluene was the most detected analyte (in 90% of the samples analyzed), with an average concentration of 0.56 microg/l. MTBE was the only dialkyl ether detected (in 15% of the samples) showing two high levels over 400 microg/l that were related to accidental fuel spill.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15088739     DOI: 10.1016/j.chroma.2004.01.046

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Three-dimensional Pd/Pt bimetallic nanodendrites on a highly porous copper foam fiber for headspace solid-phase microextraction of BTEX prior to their quantification by GC-FID.

Authors:  Milad Ghani; Saeed Masoum; Sayed Mehdi Ghoreishi
Journal:  Mikrochim Acta       Date:  2018-10-30       Impact factor: 5.833

2.  Assessment of multiple anthropogenic contaminants and their potential genotoxicity in the aquatic environment of Plitvice Lakes National Park, Croatia.

Authors:  Zorana Kljaković-Gašpić; Snježana Herceg Romanić; Tomislav Bituh; Vilena Kašuba; Irena Brčić Karačonji; Nataša Brajenović; Iva Franulović; Jasna Jurasović; Darija Klinčić; Nevenka Kopjar; Gordana Marović; Mirta Milić; Tatjana Orct; Ankica Sekovanić; Davor Želježić
Journal:  Environ Monit Assess       Date:  2018-10-31       Impact factor: 2.513

3.  Application of Headspace Solid-Phase Microextraction for Determination of Chloro-Organic Compounds in Sewage Samples.

Authors:  Grażyna Wejnerowska; Jerzy Gaca
Journal:  Toxicol Mech Methods       Date:  2008-06-23       Impact factor: 2.987

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.