Literature DB >> 15088730

Post-gel polymerization contraction of "low shrinkage" composite restoratives.

A U J Yap1, M S Soh.   

Abstract

This study compared the post-gel contraction of two "low-shrinkage" composites (InTen-S [IS], Ivoclar-Vivadent; Aelite LS [AL], BISCO Inc) and an ormocer (Admira [AM], Voco) to two conventional mini-filled composites (Renew [RN], BISCO; Z100 [ZO], 3M ESPE). A strain-monitoring device and test configuration were used to measure the linear polymerization shrinkage associated with the various composites (A2 shade) during and up to 60 minutes post light polymerization. Each specimen was irradiated for 40 seconds using a halogen curing light (Max, Dentsply-Caulk) with an intensity of 401 mW/cm2. Five specimens were made for each composite. Data was analyzed using one-way ANOVA/Scheffe's post-hoc test at significance level 0.05. The linear percentage shrinkage immediately after light polymerization and at 60 minutes post light polymerization ranged from 0.10 +/- 0.02 to 0.40 +/- 0.02% and 0.22 +/- 0.02 to 0.60 +/- 0.05%, respectively. Post-gel shrinkage ranking of the materials was as follows: immediately after light polymerization - IS < AL < AM < ZO < RN and at 60 minutes post light polymerization - IS < AL = AM < ZO < RN. The shrinkage associated with IS, AL and AM was significantly lower than for ZO and RN immediately after light polymerization and at 1, 10, 30 and 60 minutes post light polymerization. The post-gel polymerization shrinkage of IS, AL and AM was significantly lower than conventional mini-filled composites.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15088730

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  4 in total

1.  Alternative monomer for BisGMA-free resin composites formulations.

Authors:  Ana P Fugolin; Andreia B de Paula; Adam Dobson; Vincent Huynh; Rafael Consani; Jack L Ferracane; Carmem S Pfeifer
Journal:  Dent Mater       Date:  2020-05-08       Impact factor: 5.304

2.  Fracture strength of extended class I composite restorations with different restorative techniques.

Authors:  Brenda S Leyton; Rodrigo N Rached; Sergio A Ignácio; Evelise M Souza
Journal:  Odontology       Date:  2021-09-14       Impact factor: 2.634

3.  Effect of polymerisation and ageing on the incremental bond strength of ormocer-based dental materials.

Authors:  Daniel Awad; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2012-09-06       Impact factor: 3.573

4.  Effect of low-shrinkage monomers on the physicochemical properties of experimental composite resin.

Authors:  Jingwei He; Sufyan Garoushi; Pekka K Vallittu; Lippo Lassila
Journal:  Acta Biomater Odontol Scand       Date:  2018-02-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.