Literature DB >> 15085053

In vitro evaluation of the accuracy of three electronic apex locators.

C Lucena-Martín1, V Robles-Gijón, C M Ferrer-Luque, J M Navajas-Rodríguez de Mondelo.   

Abstract

The accuracy of three electronic apex locators (EALs) (Justy II, Root ZX, and Neosono Ultima EZ) is evaluated, together with the concordance of the measurements obtained by two different operators. Twenty single-root human teeth were used, sectioning the crown to gain access to the root canal. A first operator (A) determined the reference (or control) length (corresponding to the actual length) for each tooth, after which all teeth were measured individually and independently by the other two operators (B and C). The results obtained with each EAL and by each operator were in turn compared with the corresponding control length. The statistical analysis of the results showed EAL reliability in detecting the apex to vary from 80% to 85% and 85% to 90% (depending on the operator) for the Justy II and Neosono systems, respectively, whereas reliability was found to be 85% for the Root ZX device. These results, combined with a high interobserver concordance, suggest electronic root canal measurement to be an objective and acceptably reproducible technique.

Entities:  

Mesh:

Year:  2004        PMID: 15085053     DOI: 10.1097/00004770-200404000-00012

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  8 in total

1.  Precision of multi-frequency electronic apex locators.

Authors:  Roy George
Journal:  Evid Based Dent       Date:  2016-09

2.  Efficiency of an Integrated Apex Locator in Determining Working Length in Various Irrigating Solutions: An In Vivo Study.

Authors:  Rakesh Reddy Chukka; Malati Devi Bellam; Narender Reddy Marukala; Sainath Dinapadu; Naresh Kumar Konda; Jithender Nagilla
Journal:  J Pharm Bioallied Sci       Date:  2020-08-28

3.  In vitro evaluation of the accuracy of two electronic apex locators.

Authors:  Viresh Chopra; Shibani Grover; S Datta Prasad
Journal:  J Conserv Dent       Date:  2008-04

4.  In vitro evaluation of Root ZX and Raypex 6 in teeth with different apical diameters.

Authors:  Ugur Aydin; Emrah Karataslioglu; Fatih Aksoy; Cihan Yildirim
Journal:  J Conserv Dent       Date:  2015 Jan-Feb

5.  Influence of root canal curvature on the accuracy of an electronic apex locator: An in vitro study.

Authors:  Lekha Santhosh; Pooja Raiththa; Srirekha Aswathanarayana; Srinivas Panchajanya; Jayakumar Thimmaraya Reddy; Shwetha Rajanna Susheela
Journal:  J Conserv Dent       Date:  2014-11

6.  A comparative evaluation of accuracy of three electronic apex locators using histological section as gold standard: An ex vivo study.

Authors:  Divya Saxena; Suparna Ganguly Saha; Anuj Bharadwaj; Neelam Vijaywargiya; Sandeep Dubey; Shubham Kala
Journal:  J Conserv Dent       Date:  2017 Jul-Aug

7.  The Precision of Propex Pixi with Different Instruments and Coronal Preflaring Procedures.

Authors:  Inês Ferreira; Ana Cristina Braga; Irene Pina-Vaz
Journal:  Eur Endod J       Date:  2019-07-10

8.  Working Length Determination of Root Canal of Young Permanent Tooth: An In vitro Study.

Authors:  A Diwanji; As Rathore; R Arora; V Dhar; A Madhusudan; J Doshi
Journal:  Ann Med Health Sci Res       Date:  2014-07
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.