Craig P Torres1, Michael J Apicella, Peter P Yancich, M Harry Parker.
Abstract
The goal of this in vitro study was to compare the effectiveness of three different placement techniques of calcium hydroxide paste in a curved canal. An acrylic resin block with a 44-degree curvature was instrumented to a #40 Flex-R file. The canal was filled with radiopaque calcium hydroxide paste using the following techniques: group 1, the paste was injected with an Ultradent tip; group 2, the paste was injected as in group 1 and followed by a size 35 Lentulo to working length; and group 3, the paste was placed with a size 35 Lentulo only, to working length. Each technique was performed 25 times. The radiodensity of the simulated canal was measured at 1, 3, 5, and 7 mm from the canal terminus. At 1 mm, the Lentulo was significantly better than the other two techniques. At 3 mm, the Lentulo technique and the combined technique were better than the Ultradent tip alone.Entities:
Mesh:
Substances:
Year: 2004 PMID: 15085051 DOI: 10.1097/00004770-200404000-00010
Source DB: PubMed Journal: J Endod ISSN: 0099-2399 Impact factor: 4.171