Literature DB >> 15081558

Does plasma irradiation improve shear bond strength of acrylic resin to cobalt-chromium alloy?

Yukinori Maruo1, Goro Nishigawa, Morihiko Oka, Shogo Minagi, Kazuomi Suzuki, Masao Irie.   

Abstract

OBJECTIVES: Plasma treatment leads to surface modification such as the improved wettability of dental materials. Studies have suggested that plasma treatment may bring about an improvement in the shear bond strength between cobalt-chromium alloy and self-curing acrylic resin.
METHODS: Forty-eight cobalt-chromium alloy specimens were randomly divided into four groups (each of the groups consisted of 12 specimens); air abrasion, adhesive primer, adhesive primer after air abrasion, or after plasma irradiation. A self-curing acrylic resin, 2 mm thick and 3.6 mm in diameter, was processed on all specimens before storage in distilled water at 37 degrees C for 24 h. Shear bond strength values were determined at a crosshead speed of 0.5 mm/min. Data was statistically analyzed using Scheffé's test.
RESULTS: Adhesive primer clearly increased the shear bond strength compared with air abrasion (p < 0.05). The synergy of air abrasion and adhesive primer greatly increased the shear bond strength, showing a five-fold increase over air abrasion, or one and a half-fold over adhesive primer. A similar tendency in increase was observed in the adhesive primer after plasma treatment, but to a lower degree. Adhesive primer after plasma treatment showed half the shear bond strength of the treatment of adhesive primer after air abrasion (p < 0.05). Moreover, adhesive primer after plasma treatment showed a lower shear bond strength than adhesive primer alone although the difference was not statistically significant. SIGNIFICANCE: Plasma treatment does not improve adhesion between cobalt-chromium alloy and self-curing acrylic resin. Copyright 2004 Academy of Dental Materials

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15081558     DOI: 10.1016/j.dental.2003.04.001

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  4 in total

1.  Plasma in dentistry.

Authors:  Seunghee Cha; Young-Seok Park
Journal:  Clin Plasma Med       Date:  2014-05-10

2.  Effect of Fiber Laser Irradiation on the Shear Bond Strength between Acrylic Resin and Titanium.

Authors:  Fatih Mehmet Korkmaz; Selin Aycan
Journal:  Scanning       Date:  2019-09-03       Impact factor: 1.932

3.  Evaluation of shear bond strength of repair acrylic resin to Co-Cr alloy.

Authors:  Safak Külünk; Tolga Külünk; Duygu Saraç; Seda Cengiz; Seniha Baba
Journal:  J Adv Prosthodont       Date:  2014-08-14       Impact factor: 1.904

4.  Effect of zinc oxide nanoparticles on the flexural strength of polymethylmethacrylate denture base resin.

Authors:  Santhanam Vikram; N Gopi Chander
Journal:  Eur Oral Res       Date:  2020-01-01
  4 in total