Literature DB >> 15080879

The effects of different anticoagulants on routine canine plasma biochemistry.

José J Cerón1, Silvia Martínez-Subiela, Carla Hennemann, Fernando Tecles.   

Abstract

The effects of heparin, ethylenediaminetetraacetic acid (EDTA), sodium citrate and sodium fluoride/potassium oxalate on plasma biochemistry results in dogs were studied and compared with serum. Blood specimens from 10 apparently clinical healthy dogs were collected and placed in different tubes containing each anticoagulant tested. Differences in albumin, acetylcholinesterase, ionized calcium and potassium were found between serum and heparinized plasma. Most metabolites and enzymes did not show any variation, but significant decreases in electrolytes, alkaline phosphatase, acetylcholinesterase, bile acids, fructosamine and albumin were found when EDTA was used. Sodium citrate produced a 10-15% decrease in most metabolites and enzymes, possibly due to a sample dilution effect. Sodium fluoride/potassium oxalate produced haemolysis which may have influenced changes in some biochemical parameters.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15080879     DOI: 10.1016/j.tvjl.2003.09.009

Source DB:  PubMed          Journal:  Vet J        ISSN: 1090-0233            Impact factor:   2.688


  5 in total

1.  Effects of hemolysis, lipemia, hyperbilirrubinemia, and anticoagulants in canine C-reactive protein, serum amyloid A, and ceruloplasmin assays.

Authors:  Silvi Martínez-Subiela; Jose J Cerón
Journal:  Can Vet J       Date:  2005-07       Impact factor: 1.008

2.  A guide for measurement of circulating metabolic hormones in rodents: Pitfalls during the pre-analytical phase.

Authors:  Maximilian Bielohuby; Sarah Popp; Martin Bidlingmaier
Journal:  Mol Metab       Date:  2012-08-09       Impact factor: 7.422

3.  Plasma biochemistry of ostrich (Struthio camelus): effects of anticoagulants and comparison with serum.

Authors:  M Mohri; R Narenji Sani; R Masoodi
Journal:  Trop Anim Health Prod       Date:  2008-11-15       Impact factor: 1.559

4.  Head-to-Head Comparison of Different Blood Collecting Tubes for Quantification of Alzheimer's Disease Biomarkers in Plasma.

Authors:  Lijun Jiang; Xulong Ding; Wenxiao Wang; Xiaobin Yang; Tao Li; Peng Lei
Journal:  Biomolecules       Date:  2022-08-28

Review 5.  Serum paraoxonase 1 (PON1) measurement: an update.

Authors:  Jose J Ceron; Fernando Tecles; Asta Tvarijonaviciute
Journal:  BMC Vet Res       Date:  2014-03-25       Impact factor: 2.741

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.