Literature DB >> 15078765

Pulmonary function and sputum production in patients with cystic fibrosis: a pilot study comparing the PercussiveTech HF device and standard chest physiotherapy.

John H Marks1, Karyl L Hare, Robert A Saunders, Douglas N Homnick.   

Abstract

STUDY
OBJECTIVE: To compare the PercussiveTech HF (PTHF) device (Vortran Medical Technology 1; Sacramento, CA) to standard manual chest physiotherapy (CPT) with respect to acute changes in pulmonary function, sputum production, and pulse oximetry in patients with cystic fibrosis (CF).
DESIGN: Randomized crossover.
SETTING: University-affiliated, community-based CF center. PARTICIPANTS: Ten clinically stable patients with CF (age range, 10 to 21 years; mean age, 15.3 years) with Shwachman scores from 55 to 95 (mean 75).
INTERVENTIONS: Two treatment regimens were used: 2.5 mg of albuterol delivered via updraft nebulizer followed by standard CPT, and 2.5 mg of albuterol delivered via the PTHF device without CPT.
RESULTS: Outcome measures included pulmonary function test (PFT) results 4 h after treatment and quantitative sputum production during the 4 h after treatment. Pulse oximetry was performed during treatment. A patient satisfaction questionnaire was administered at the end of the study. No PFT parameters were significantly changed 4 h after CPT or PTHF, although there was a trend to decreasing residual volume after both treatments. There was a trend for more sputum production after PTHF compared to CPT, but this did not reach statistical significance. There were no episodes of hemoglobin-oxygen desaturation during or after either treatment. One patient had minor hemoptysis after CPT. No adverse effects occurred after PTHF. Eight patients found the PTHF device easy to use, and six patients would prefer the PTHF device to CPT.
CONCLUSIONS: The PTHF device appears to be a safe and effective method of airway clearance in CF patients in this small pilot study.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15078765     DOI: 10.1378/chest.125.4.1507

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  7 in total

1.  Oscillating devices for airway clearance in people with cystic fibrosis.

Authors:  Lisa Morrison; Stephanie Milroy
Journal:  Cochrane Database Syst Rev       Date:  2020-04-30

Review 2.  Oscillating devices for airway clearance in people with cystic fibrosis.

Authors:  Lisa Morrison; Stephanie Innes
Journal:  Cochrane Database Syst Rev       Date:  2017-05-04

3.  Airway clearance devices for cystic fibrosis: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2009-11-01

Review 4.  Chest physiotherapy compared to no chest physiotherapy for cystic fibrosis.

Authors:  Louise Warnock; Alison Gates
Journal:  Cochrane Database Syst Rev       Date:  2015-12-21

5.  Feasibility and safety of intrapulmonary percussive ventilation in spontaneously breathing, non-ventilated patients in critical care: A retrospective pilot study.

Authors:  Anwar Hassan; Maree Milross; William Lai; Deepa Shetty; Jennifer Alison; Stephen Huang
Journal:  J Intensive Care Soc       Date:  2020-03-12

6.  Physiotherapeutic management strategies for the treatment of cystic fibrosis in adults.

Authors:  Tracey Daniels
Journal:  J Multidiscip Healthc       Date:  2010-11-19

7.  Outcome measures for airway clearance techniques in children with chronic obstructive lung diseases: a systematic review.

Authors:  Eline Lauwers; Kris Ides; Kim Van Hoorenbeeck; Stijn Verhulst
Journal:  Respir Res       Date:  2020-08-17
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.