Literature DB >> 15076192

Functional, mechanical and geometrical adaptation of the arterial wall of a non-axisymmetric artery in vitro.

Gabriela Montorzi1, Paolo Silacci, Martin Zulliger, Nikos Stergiopulos.   

Abstract

OBJECTIVE: Vascular remodeling is an adaptive response to variations in the hemodynamic environment acting on the arterial wall. Remodeling translates into changes of structure, geometry and mechanical properties of the artery. Our aim was to study the remodeling response of pig right common carotid arteries in vitro.
METHODS: In vivo right carotid arteries are exposed to a non-uniform hemodynamic environment and exhibit a strong wall asymmetry in the circumferential direction that allows the study of two regions separately, as the artery remodels under in vitro perfusion. Porcine right common carotid arteries were cultured during 1 day (n = 6), 3 days (n = 6) or 8 days (n = 6) in an in vitro organ culture system, at a constant perfusion pressure of 100 mmHg. Geometrical, histological, biomechanical and biological analysis of the perfused segments was performed at the end of each study.
RESULTS: Smooth muscle cell nuclei density and wall thickness remain constant along the culture periods. Elastin and collagen are significantly redistributed to equilibrate their relative content along the vessel circumference. The distensibility profile is significantly different at day 8. Matrix metalloproteinase-2 expression and activity increase significantly at days 3 and 8.
CONCLUSION: The non-axisymmetric arterial wall adapts to a uniform hemodynamic environment by redistributing the structural components of the extracellular matrix. The changes of collagen and elastin density may result from a vascular remodeling process involving matrix metalloproteinase-2 up-regulation and enzymatic activity. The remodeling response results in a new vascular wall configuration that is more distensible at physiological pressures (30-120 mmHg) and stiffer at higher pressures.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15076192     DOI: 10.1097/00004872-200402000-00018

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  3 in total

1.  Factors affecting outflow facility calculations.

Authors:  Baohe Tian; Yujie Hu; B'Ann T Gabelt; Paul L Kaufman
Journal:  Exp Eye Res       Date:  2006-10-06       Impact factor: 3.467

Review 2.  Animal, in vitro, and ex vivo models of flow-dependent atherosclerosis: role of oxidative stress.

Authors:  Amir Rezvan; Chih-Wen Ni; Noah Alberts-Grill; Hanjoong Jo
Journal:  Antioxid Redox Signal       Date:  2010-12-04       Impact factor: 8.401

3.  The perianeurysmal environment: influence on saccular aneurysm shape and rupture.

Authors:  D San Millán Ruíz; H Yilmaz; A R Dehdashti; A Alimenti; N de Tribolet; D A Rüfenacht
Journal:  AJNR Am J Neuroradiol       Date:  2006-03       Impact factor: 3.825

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.