Literature DB >> 15072215

Numerical study on an equivalent source model for inhomogeneous magnetic field dosimetry in the low-frequency range.

Shinichiro Nishizawa1, Hans-Oliver Ruoss, Friedrich M Landstorfer, Osamu Hashimoto.   

Abstract

A new equivalent numerical source model is proposed for efficient dosimetric investigations in the low-frequency range. This approach allows the reproduction of complicated inhomogeneous magnetic field distributions around electronic appliances with full generality (i.e., supports three-dimensional vector fields). This paper investigates the accuracy of the equivalent source model using the geometry-based numerical reference model of a current loop to simulate the magnetic field distribution of a real electronic appliance. Good agreement between the equivalent source model and the reference is obtained with regard to the magnetic field distribution and the induced electric current density in a homogeneous human body model, respectively.

Entities:  

Mesh:

Year:  2004        PMID: 15072215     DOI: 10.1109/TBME.2004.824129

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  1 in total

1.  Estimation of radiofrequency power leakage from microwave ovens for dosimetric assessment at nonionizing radiation exposure levels.

Authors:  Peio Lopez-Iturri; Silvia de Miguel-Bilbao; Erik Aguirre; Leire Azpilicueta; Francisco Falcone; Victoria Ramos
Journal:  Biomed Res Int       Date:  2015-02-01       Impact factor: 3.411

  1 in total