Literature DB >> 15072183

Accurate scatter correction for transmission computed tomography using an uncollimated line array source.

Akihiro Kojima1, Masanori Matsumoto, Seiji Tomiguchi, Noboru Katsuda, Yasuyuki Yamashita, Nobutoku Motomura.   

Abstract

We investigated scatter correction in transmission computed tomography (TCT) imaging by the combination of an uncollimated transmission source and a parallel-hole collimator. We employed the triple energy window (TEW) as the scatter correction and found that the conventional TEW method, which is accurate in emission computed tomography (ECT) imaging, needs some modification in TCT imaging based on our phantom studies. In this study a Tc-99m uncollimated line array source (area: 55 cm x 40 cm) was attached to one camera head of a dual-head gamma camera as a transmission source, and TCT data were acquired with a low-energy, general purpose (LEGP), parallel-hole collimator equipped on the other camera head. The energy spectra for 140 keV-photons transmitted through various attenuating material thicknesses were measured and analyzed for scatter fraction. The results of the energy spectra showed that the photons transmitted had an energy distribution that constructs a scatter peak within the 140 keV-photopeak energy window. In TCT imaging with a cylindrical water phantom, the conventional TEW method with triangle estimates (subtraction factor, K = 0.5) was not sufficient for accurate scatter correction (micro = 0.131 cm(-1) for water), whereas the modified TEW method with K = 1.0 gave the accurate attenuation coefficient of 0.153 cm(-1) for water. For the TCT imaging with the combination of the uncollimated Tc-99m line array source and parallel hole collimator, the modified TEW method with K = 1.0 gives the accurate TCT data for quantitative SPECT imaging in comparison with the conventional TEW method with K = 0.5.

Entities:  

Mesh:

Year:  2004        PMID: 15072183     DOI: 10.1007/bf02985613

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  2 in total

1.  The Effect of Milk, Water and Lemon Juice on Various Subdiaphragmatic Activity-Related Artifacts in Myocardial Perfusion Imaging.

Authors:  Hadi Malek; Raheleh Hedayati; Nahid Yaghoobi; Ahmad Bitarafan-Rajabi; Seyed Hassan Firoozabadi; Feridoon Rastgou
Journal:  Res Cardiovasc Med       Date:  2015-09-14

2.  Scatter correction for heart SPECT images using TEW method.

Authors:  Vahid Changizi; Abbas Takavar; Azadeh Babakhani; Mahdi Sohrabi
Journal:  J Appl Clin Med Phys       Date:  2008-06-23       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.