Literature DB >> 15071860

[Thoracoabdominal aortic aneurysm repair after detection of the Adamkiewicz artery by magnetic resonance angiography; a way to shorten operating time and improve outcome].

Y Hachiro1, N Kawaharada, K Morishita, J Fukada, Y Fujisawa, Y Kurimoto, T Abe.   

Abstract

Surgical results were compared between 18 patients (group A) who underwent preoperative anatomic characterization of the Adamkiewicz artery by magnetic resonance angiography (MRA) and 38 patients (group B) without such imaging. In group A, intercostal or lumbar arteries related to the aneurysm were reattached to the graft only when they represented the origin of the Adamkiewicz artery. In group B, reconstruction from the Th 7 intercostal and the L2 lumbar arteries was performed whenever possible. In-hospital mortality was 16.7% in group A and 15.8% in group B. Total aortic clamp time and operating time were only 84 and 437 min in group A, compared with 134 and 589 min in group B. Three patients showed postoperative paraplegia in group B. No spinal cord injury occurred in patients whose artery had been detected preoperatively. Preoperative anatomic delineation of the Adamkiewicz artery by MRA can reduce risk of ischemic injury to the spinal cord and decrease operating time required for repair of thoracoabdominal aortic aneurysms.

Entities:  

Mesh:

Year:  2004        PMID: 15071860

Source DB:  PubMed          Journal:  Kyobu Geka        ISSN: 0021-5252


  2 in total

1.  Identifying the Adamkiewicz artery using 3-T time-resolved magnetic resonance angiography: its role in addition to multidetector computed tomography angiography.

Authors:  Hidenobu Takagi; Hideki Ota; Yutaka Natsuaki; Yoshiaki Komori; Koki Ito; Yoshikatsu Saiki; Kei Takase
Journal:  Jpn J Radiol       Date:  2015-10-26       Impact factor: 2.374

2.  Simultaneous Evaluation of the Whole Aorta and Artery of Adamkiewicz by MDCT.

Authors:  Kei Takase
Journal:  Ann Vasc Dis       Date:  2011-11-30
  2 in total