Literature DB >> 15070452

Continuous intra-arterial blood gas monitoring in rats.

M A Pakulla1, D Obal, S A Loer.   

Abstract

Studies on lung injury and its treatment options are often performed on small animals like rats. Because conventional blood gas analyses may not detect rapid changes in gas exchange during respiratory distress syndrome and intermittent blood withdrawal can result in hypo-volaemia and anaemia, we tested the applicability and accuracy of a continuous intravascular blood gas monitor (Paratrend 7+). Anaesthetized and ventilated rats with a body weight of 398 +/-45 g (n =22) had a 20-gauge cannula inserted in both carotid arteries. A photochemical blood gas sensor for continuous measurement (Paratrend 7+) was advanced into the aorta via the left carotid artery. Blood was sampled for intermittent blood gas analysis by means of the right carotid artery. Arterial pO(2) was varied by applying different inspiratory oxygen concentrations, and arterial pCO(2) by applying different respiratory rates. Paired blood gas measurements (n =136) were analysed over a wide range of pO(2) values (5.3-76.8 kPa). We found an acceptable correlation for pO(2) (r(2)=0.98), pCO(2) (r(2)=0.96) and pH (r(2)=0.92). The calculated bias and imprecision for pO(2) was -1.0 +/- 3.3 kPa, for pCO(2) 0.04 +/- 0.28 kPa and for hydrogen ion concentration -0.05 +/-2.2 nmol/l. We conclude that in rats, continuous blood gas monitoring with a photochemical blood gas sensor provides pO(2), pCO(2) and pH measurements with acceptable accuracy.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15070452     DOI: 10.1258/002367704322968803

Source DB:  PubMed          Journal:  Lab Anim        ISSN: 0023-6772            Impact factor:   2.471


  3 in total

1.  Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications.

Authors:  Andreas Steinegger; Otto S Wolfbeis; Sergey M Borisov
Journal:  Chem Rev       Date:  2020-11-04       Impact factor: 60.622

2.  Enhancing analytical accuracy of intravascular electrochemical oxygen sensors via nitric oxide release using S-nitroso-N-acetyl-penicillamine (SNAP) impregnated catheter tubing.

Authors:  M M McCabe; P Hala; A Rojas-Pena; O Lautner-Csorba; T C Major; H Ren; R H Bartlett; E J Brisbois; M E Meyerhoff
Journal:  Talanta       Date:  2019-06-25       Impact factor: 6.057

3.  Hydrochloric acid-induced lung injury: effects of early partial liquid ventilation on survival rate, gas exchange, and pulmonary neutrophil accumulation.

Authors:  Michael A Pakulla; David Seidel; Detlef Obal; Stephan A Loer
Journal:  Intensive Care Med       Date:  2004-09-21       Impact factor: 17.440

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.