Literature DB >> 15068606

Fusion imaging in nuclear medicine--applications of dual-modality systems in oncology.

Orazio Schillaci1, Giovanni Simonetti.   

Abstract

Medical imaging has become of the utmost importance in evaluating patients with cancer. Single-photon emission computed tomography (SPECT) and positron emission tomography (PET) are accurate methods for detecting cancer and related metabolic abnormalities, but they often do not provide the anatomical landmarks needed to precisely localize lesions. Magnetic resonance imaging (MRI) and computed tomography (CT) scan, on the other hand, offer excellent anatomic detail but are less sensitive because they do not provide functional detail. Fusion imaging combines functional studies with morphological ones, so overcoming the drawbacks of both modalities. Software-based fusion of independently performed scintigraphic and radiological images has proven time consuming and impractical for routine use. Recently, dual-modality integrated imaging systems (SPECT/CT and PET/CT) have been developed: the acquired images are coregistered by means of the hardware in the same session. These new devices can be particularly useful for tumour imaging. The anatomical images provide precise localization and allow the exclusion of disease in sites of physiologic tracers' accumulation for SPECT and PET findings. Hybrid imaging in oncological applications has been very encouraging, indicating that these systems are suited for routine use in clinical practice. In fact, fused images provide additional information that improves diagnostic accuracy and impacts on patient management.

Entities:  

Mesh:

Year:  2004        PMID: 15068606     DOI: 10.1089/108497804773391621

Source DB:  PubMed          Journal:  Cancer Biother Radiopharm        ISSN: 1084-9785            Impact factor:   3.099


  14 in total

1.  Influence of PSA, PSA velocity and PSA doubling time on contrast-enhanced 18F-choline PET/CT detection rate in patients with rising PSA after radical prostatectomy.

Authors:  Orazio Schillaci; Ferdinando Calabria; Mario Tavolozza; Cristiana Ragano Caracciolo; Enrico Finazzi Agrò; Roberto Miano; Antonio Orlacchio; Roberta Danieli; Giovanni Simonetti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-01-10       Impact factor: 9.236

2.  Single-photon Emission Computed Tomography-Computed Tomography Using 99mTc-labeled Leukocytes for Evaluating Infection Associated with a Cranial Implant in a Rhesus Macaque (Macaca mulatta).

Authors:  Kathryn A Guerriero; Steven R Wilson; Albert J Sinusas; Lawrence Saperstein; Andcaroline J Zeiss
Journal:  Comp Med       Date:  2019-04-01       Impact factor: 0.982

Review 3.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

4.  Clinical study of the application of SPECT, CT, and SPECT/CT for diagnosing rib diseases.

Authors:  Runqing Duan; Hongcheng Shi
Journal:  Jpn J Radiol       Date:  2015-01-29       Impact factor: 2.374

5.  Utility of (99m)Tc-MDP hybrid SPECT-CT for diagnosis of skull base osteomyelitis: comparison with planar bone scintigraphy, SPECT, and CT.

Authors:  Punit Sharma; Krishan Kant Agarwal; Sourav Kumar; Harmandeep Singh; Chandrasekhar Bal; Arun Malhotra; Rakesh Kumar
Journal:  Jpn J Radiol       Date:  2012-10-12       Impact factor: 2.374

6.  SPECT/CT in the Diagnosis of Skull Base Osteomyelitis.

Authors:  Nishikant Avinash Damle; Rakesh Kumar; Praveen Kumar; Sriram Jaganathan; Manish Patnecha; Chandrasekhar Bal; Gurupad Bandopadhyaya; Arun Malhotra
Journal:  Nucl Med Mol Imaging       Date:  2011-05-12

7.  Mapping of treatment-induced apoptosis in normal structures: 99mTc-Hynic-rh-annexin V SPECT and CT image fusion.

Authors:  Marina S Kartachova; Renato A Valdés Olmos; Rick L M Haas; Frank J P Hoebers; Michiel W van den Brekel; Nico van Zandwijk; Marcel van Herk; Marcel Verheij
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-04-04       Impact factor: 9.236

8.  Evaluation of tilted cone-beam CT orbits in the development of a dedicated hybrid mammotomograph.

Authors:  P Madhav; D J Crotty; R L McKinley; M P Tornai
Journal:  Phys Med Biol       Date:  2009-05-28       Impact factor: 3.609

Review 9.  Interrogating tumor metabolism and tumor microenvironments using molecular positron emission tomography imaging. Theranostic approaches to improve therapeutics.

Authors:  Orit Jacobson; Xiaoyuan Chen
Journal:  Pharmacol Rev       Date:  2013-09-24       Impact factor: 25.468

10.  Diagnosing osteomyelitis in the diabetic foot: a pilot study to examine the sensitivity and specificity of Tc(99m) white blood cell-labelled single photon emission computed tomography/computed tomography.

Authors:  Mallory M Przybylski; Samantha Holloway; Steven D Vyce; Antonio Obando
Journal:  Int Wound J       Date:  2014-06-26       Impact factor: 3.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.