Literature DB >> 15065910

Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy.

Valentina Quaresima1, Marco Ferrari, Maria Angela Franceschini, Matthew L Hoimes, Sergio Fantini.   

Abstract

Muscle blood flow (MBF) and muscle oxygen saturation (SmO(2)) were measured at eight locations (four proximal, four distal) over a 4 x 8 cm(2) area of the vastus lateralis at rest and immediately after isometric, maximal quadriceps contraction using multichannel, frequency-domain, near-infrared spectroscopy. A venous occlusion was applied 20 s before the end of the exercise, so that the venous-occlusion-induced increase in total hemoglobin was recorded without any delay after the end of the exercise. Therefore, we were able to investigate the relationship between the exercise-induced changes in vastus lateralis MBF and SmO(2). After exercise, MBF increased significantly at each measured location. Comparing the MBF values measured at the end of exercise in the proximal and distal regions, we observed that only one proximal region had a significantly higher MBF than the corresponding distal one. The maximum desaturation measured during exercise was positively correlated with the postexercise to pre-exercise MBF ratio in both the proximal (P=0.016) and distal (P=0.0065) regions. These data confirm that frequency-domain tissue oximeters are noninvasive, powerful tools to investigate the spatial and temporal features of muscle blood flow and oxygenation, with potential applications in areas of pathophysiology. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15065910     DOI: 10.1117/1.1646417

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  8 in total

1.  Feasibility of overnight electrical stimulation-induced muscle activation in people with a spinal cord injury. A Pilot study.

Authors:  Christof A J Smit; Frank Berenpas; Sonja de Groot; Janneke M Stolwijk-Swuste; Thomas W J Janssen
Journal:  Spinal Cord Ser Cases       Date:  2020-01-24

Review 2.  Clinical applications of near-infrared diffuse correlation spectroscopy and tomography for tissue blood flow monitoring and imaging.

Authors:  Yu Shang; Ting Li; Guoqiang Yu
Journal:  Physiol Meas       Date:  2017-02-15       Impact factor: 2.833

3.  The Effect of Prolonged Walking With Intermittent Standing on Erector Spinae and Soleus Muscle Oxygenation and Discomfort.

Authors:  April J Chambers; Justin M Haney; Theodore Huppert; Mark S Redfern
Journal:  J Sports Sci Med       Date:  2019-06-01       Impact factor: 2.988

Review 4.  Review of early development of near-infrared spectroscopy and recent advancement of studies on muscle oxygenation and oxidative metabolism.

Authors:  Takafumi Hamaoka; Kevin K McCully
Journal:  J Physiol Sci       Date:  2019-07-29       Impact factor: 2.781

5.  Feasibility of overnight electrical stimulation-induced muscle activation in people with a spinal cord injury. A Pilot study.

Authors:  Christof A J Smit; Frank Berenpas; Sonja de Groot; Janneke M Stolwijk-Swuste; Thomas W J Janssen
Journal:  Spinal Cord Ser Cases       Date:  2020-01-24

6.  Spectral and spatial dependence of
diffuse optical signals in response to
peripheral nerve stimulation.

Authors:  Debbie K Chen; M Kelley Erb; Yunjie Tong; Yang Yu; Angelo Sassaroli; Peter R Bergethon; Sergio Fantini
Journal:  Biomed Opt Express       Date:  2010-09-16       Impact factor: 3.732

7.  Local increase in trapezius muscle oxygenation during and after acupuncture.

Authors:  Masaki Ohkubo; Takafumi Hamaoka; Masatugu Niwayama; Norio Murase; Takuya Osada; Ryotaro Kime; Yuko Kurosawa; Ayumi Sakamoto; Toshihito Katsumura
Journal:  Dyn Med       Date:  2009-03-16

8.  Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle.

Authors:  Parisa Farzam; Zack Starkweather; Maria A Franceschini
Journal:  Physiol Rep       Date:  2018-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.