Literature DB >> 15065185

Does ultrasound examination when the cervix is unfavorable improve the prediction of failed labor induction?

H Roman1, E Verspyck, L Vercoustre, S Degre, J Y Col, J M Firmin, P Caron, L Marpeau.   

Abstract

OBJECTIVE: To compare the Bishop score, ultrasound cervical parameters and fetal fibronectin assessment for predicting failed labor induction when the cervix is unfavorable.
METHOD: A prospective observational study was performed in 106 consecutive pregnant women with a Bishop score < or =5 undergoing labor induction. Assessment of fetal fibronectin and ultrasound measurement of cervical length, cervical wedging and cervical lip areas were performed. The relationship between these parameters and failure of labor induction was determined.
RESULTS: Failure of labor induction was defined as failure to reach a cervical dilatation of > or =5 cm, and it occurred in 16 patients (15.1%). Induction failure was associated with low Bishop scores before (P = 0.004) and 6 h after the start of induction (P = 0.007), increased clinical cervical length (P = 0.02) and increased ultrasound anterior cervical lip area (P = 0.04). The logistic regression model identified the Bishop score before induction (odds ratio = 2.25; 95% CI, 1.30-3.91; P = 0.003) and the clinical cervical length (odds ratio = 3.95; 95% CI, 1.3-11.7; P = 0.01) as being independent predictors of failed induction. To predict an induction failure, the best Bishop score cut-off value was 4, with a sensitivity of 87.5%, a specificity of 45.6%, a likelihood ratio of 1.58, a positive predictive value of 22.2% and a negative predictive value of 95.4%.
CONCLUSION: Compared with the Bishop score, cervical length by ultrasound is not a better predictor for the outcome of labor induction in an unfavorable cervix. Nevertheless, the Bishop score appears to be of poor predictive value for failed induction of labor. Copyright 2004 ISUOG.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15065185     DOI: 10.1002/uog.1008

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  4 in total

1.  Manipal Cervical Scoring System by Transvaginal Ultrasound in Predicting Successful Labour Induction.

Authors:  Neha Bajpai; Rajesh Bhakta; Pratap Kumar; Lavanya Rai; Shripad Hebbar
Journal:  J Clin Diagn Res       Date:  2015-05-01

2.  Transvaginal ultrasonographic cervical measurement in predicting failed labor induction and cesarean delivery for failure to progress in nulliparous women.

Authors:  Kyo Hoon Park
Journal:  J Korean Med Sci       Date:  2007-08       Impact factor: 2.153

3.  Reference range of the weekly uterine cervical length at 8 to 38 weeks of gestation in the center of Iran.

Authors:  Esmat Jafari-Dehkordi; Atoosa Adibi; Mehri Sirus
Journal:  Adv Biomed Res       Date:  2015-05-29

4.  Cervical length measured by transvaginal ultrasonography versus Bishop score to predict successful labour induction in term pregnancies.

Authors:  Y J B Groeneveld; A M Bohnen; A M Van Heusden
Journal:  Facts Views Vis Obgyn       Date:  2010
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.