Literature DB >> 15065171

Time-of-flight quantitative measurements of blood flow in mouse hindlimbs.

Shawn Wagner1, Armin Helisch, Georg Bachmann, Wolfgang Schaper.   

Abstract

PURPOSE: To evaluate the feasibility of using time-of-flight (TOF) imaging to directly measure hindlimb blood flow in a mouse model of peripheral vascular disease.
MATERIALS AND METHODS: Four tubes were imaged simultaneously (diameters = 0.39 mm, 0.59 mm, and two at 1.46 mm) with a 1.0 mM copper sulfate solution for 19 flow velocities. In vivo measurements were performed in the hindlimbs of three mouse strains-C57BL/6 (N = 5), BALB/c (N = 5), and 129S2/Sv (N = 5)-three weeks after femoral artery ligation with a calibration standard.
RESULTS: The flow phantom showed that the intensity was linear (r2 = 0.92) over the pertinent blood flow velocities in the mouse hindlimbs. Measurements of the blood flow in the distal hindlimbs in different strains of mice (combination of both the venous and arterial flows) were obtained 21 days after right-sided femoral artery occlusion. The results showed that under similar conditions of anesthesia and temperature, SV129 mice on the nonligated side had the highest flows (0.50 +/- 0.07 mL/minute), followed by C57BL/6 (0.28 +/- 0.04 mL/minute) and BALB/c (0.23 +/- 0.05 mL/minute), P < 0.02. The ligated side measurements (SV129, 0.31 +/- 0.05 mL/minute (P = 0.02); C57BL/6, 0.21 +/- 0.02 mL/minute (P = 0.13); and BALB/c, 0.12 +/- 0.02 mL/minute (P= 0.06)) showed a trend in BALB/c and C57BL/6 and significant differences in SV129 for incomplete recovery three weeks after surgery, compared to the nonligated side.
CONCLUSION: Two-dimensional TOF imaging permits quantitative in vivo measurements of hindlimb blood flow in a mouse model of peripheral vascular disease without the need of contrast injection, offering advantages of serial imaging not limited by tissue penetration. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15065171     DOI: 10.1002/jmri.20025

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  7 in total

1.  Improved diffuse fluorescence flow cytometer prototype for high sensitivity detection of rare circulating cells in vivo.

Authors:  Noah Pestana; Luke J Mortensen; Judith P Runnels; Dwayne Vickers; Shashi K Murthy; Charles P Lin; Mark Niedre
Journal:  J Biomed Opt       Date:  2013-07       Impact factor: 3.170

2.  Instrument for fluorescence sensing of circulating cells with diffuse light in mice in vivo.

Authors:  Eric Zettergren; Dwayne Vickers; Judith Runnels; Shashi K Murthy; Charles P Lin; Mark Niedre
Journal:  J Biomed Opt       Date:  2012-03       Impact factor: 3.170

3.  Diffuse fluorescence fiber probe for in vivo detection of circulating cells.

Authors:  Vivian Pera; Xuefei Tan; Judith Runnels; Neha Sardesai; Charles P Lin; Mark Niedre
Journal:  J Biomed Opt       Date:  2017-03-01       Impact factor: 3.170

4.  Validation of a device for fluorescence sensing of rare circulating cells with diffusive light in an optical flow phantom model.

Authors:  Eric Zettergren; Dwayne Vickers; Judith Runnels; Charles P Lin; Mark J Niedre
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

5.  Tomographic sensing and localization of fluorescently labeled circulating cells in mice in vivo.

Authors:  Eric Zettergren; Tushar Swamy; Judith Runnels; Charles P Lin; Mark Niedre
Journal:  Phys Med Biol       Date:  2012-07-02       Impact factor: 3.609

6.  Transplantation of bone marrow derived monocytes: a novel approach for augmentation of arteriogenesis in a murine model of femoral artery ligation.

Authors:  Alexander Francke; Soenke Weinert; Ruth H Strasser; Ruediger C Braun-Dullaeus; Joerg Herold
Journal:  Am J Transl Res       Date:  2013-03-28       Impact factor: 4.060

7.  Quantification of blood flow in internal cerebral artery by optical flow method on digital subtraction angiography in comparison with time-of-flight magnetic resonance angiography.

Authors:  Tzung-Chi Huang; Chih-Kai Chang; Chun-Han Liao; Yung-Jen Ho
Journal:  PLoS One       Date:  2013-01-24       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.