Literature DB >> 15064296

Constrained sessile drop as a new configuration to measure low surface tension in lung surfactant systems.

Laura M Y Yu1, James J Lu, Yawen W Chan, Amy Ng, Ling Zhang, Mina Hoorfar, Zdenka Policova, Karina Grundke, A Wilhelm Neumann.   

Abstract

Existing methodology for surface tension measurements based on drop shapes suffers from the shortcoming that it is not capable to function at very low surface tension if the liquid dispersion is opaque, such as therapeutic lung surfactants at clinically relevant concentrations. The novel configuration proposed here removes the two big restrictions, i.e., the film leakage problem that is encountered with such methods as the pulsating bubble surfactometer as well as the pendant drop arrangement, and the problem of the opaqueness of the liquid, as in the original captive bubble arrangement. A sharp knife edge is the key design feature in the constrained sessile drop that avoids film leakage at low surface tension. The use of the constrained sessile drop configuration in conjunction with axisymmetric drop shape analysis to measure surface tension allows complete automation of the setup. Dynamic studies with lung surfactant can be performed readily by changing the volume of a sessile drop, and thus the surface area, by means of a motor-driven syringe. To illustrate the validity of using this configuration, experiments were performed using an exogenous lung surfactant preparation, bovine lipid extract surfactant (BLES) at 5.0 mg/ml. A comparison of results obtained for BLES at low concentration between the constrained sessile drop and captive bubble arrangement shows excellent agreement between the two approaches. When the surface area of the BLES film (0.5 mg/ml) was compressed by about the same amount in both systems, the minimum surface tensions attained were identical within the 95% confidence limits.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15064296     DOI: 10.1152/japplphysiol.00089.2003

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  8 in total

1.  Phase Transitions in Dipalmitoylphosphatidylcholine Monolayers.

Authors:  Yi Y Zuo; Rimei Chen; Xianju Wang; Jinlong Yang; Zdenka Policova; A Wilhelm Neumann
Journal:  Langmuir       Date:  2016-08-09       Impact factor: 3.882

2.  Biophysical influence of airborne carbon nanomaterials on natural pulmonary surfactant.

Authors:  Russell P Valle; Tony Wu; Yi Y Zuo
Journal:  ACS Nano       Date:  2015-05-06       Impact factor: 15.881

3.  Alveolar injury and regeneration following deletion of ABCA3.

Authors:  Tara N Rindler; Courtney A Stockman; Alyssa L Filuta; Kari M Brown; John M Snowball; Wenjia Zhou; Ruud Veldhuizen; Erika M Zink; Sydney E Dautel; Geremy Clair; Charles Ansong; Yan Xu; James P Bridges; Jeffrey A Whitsett
Journal:  JCI Insight       Date:  2017-12-21

4.  Automated Droplet Manipulation Using Closed-Loop Axisymmetric Drop Shape Analysis.

Authors:  Kyle Yu; Jinlong Yang; Yi Y Zuo
Journal:  Langmuir       Date:  2016-05-09       Impact factor: 3.882

5.  Antimicrobial and biophysical properties of surfactant supplemented with an antimicrobial peptide for treatment of bacterial pneumonia.

Authors:  Brandon J H Banaschewski; Edwin J A Veldhuizen; Eleonora Keating; Henk P Haagsman; Yi Y Zuo; Cory M Yamashita; Ruud A W Veldhuizen
Journal:  Antimicrob Agents Chemother       Date:  2015-03-09       Impact factor: 5.191

6.  Long-chain acyl-CoA dehydrogenase deficiency as a cause of pulmonary surfactant dysfunction.

Authors:  Eric S Goetzman; John F Alcorn; Sivakama S Bharathi; Radha Uppala; Kevin J McHugh; Beata Kosmider; Rimei Chen; Yi Y Zuo; Megan E Beck; Richard W McKinney; Helen Skilling; Kristen R Suhrie; Anuradha Karunanidhi; Renita Yeasted; Chikara Otsubo; Bryon Ellis; Yulia Y Tyurina; Valerian E Kagan; Rama K Mallampalli; Jerry Vockley
Journal:  J Biol Chem       Date:  2014-03-03       Impact factor: 5.157

7.  Molecular and biophysical mechanisms behind the enhancement of lung surfactant function during controlled therapeutic hypothermia.

Authors:  C Autilio; M Echaide; A Cruz; C García-Mouton; A Hidalgo; E Da Silva; D De Luca; Jorid B Sørli; J Pérez-Gil
Journal:  Sci Rep       Date:  2021-01-12       Impact factor: 4.379

8.  mTORC1 is a mechanosensor that regulates surfactant function and lung compliance during ventilator-induced lung injury.

Authors:  Hyunwook Lee; Qinqin Fei; Adam Streicher; Wenjuan Zhang; Colleen Isabelle; Pragi Patel; Hilaire C Lam; Antonio Arciniegas-Rubio; Miguel Pinilla-Vera; Diana P Amador-Munoz; Diana Barragan-Bradford; Angelica Higuera-Moreno; Rachel K Putman; Lynette M Sholl; Elizabeth P Henske; Christopher M Bobba; Natalia Higuita-Castro; Emily M Shalosky; R Duncan Hite; John W Christman; Samir N Ghadiali; Rebecca M Baron; Joshua A Englert
Journal:  JCI Insight       Date:  2021-07-22
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.