Literature DB >> 15063861

Intracranial vessel segmentation from time-of-flight MRA using pre-processing of the MIP Z-buffer: accuracy of the ZBS algorithm.

Brian E Chapman1, Janet O Stapelton, Dennis L Parker.   

Abstract

We evaluate the accuracy of a vascular segmentation algorithm which uses continuity in the maximum intensity projection (MIP) depth Z-buffer as a pre-processing step to generate a list of 3D seed points for further segmentation. We refer to the algorithm as Z-buffer segmentation (ZBS). The pre-processing of the MIP Z-buffer is based on smoothness measured using the minimum chi-square value of a least square fit. Points in the Z-buffer with chi-square values below a selected threshold are used as seed points for 3D region growing. The ZBS algorithm couples spatial continuity information with intensity information to create a simple yet accurate segmentation algorithm. We examine the dependence of the segmentation on various parameters of the algorithm. Performance is assessed in terms of the inclusion/exclusion of vessel/background voxels in the segmentation of intracranial time-of-flight MRA images. The evaluation is based on 490,256 voxels from 14 patients which were classified by an observer. ZBS performance was compared to simple thresholding and to segmentation based on vessel enhancement filtering. The ZBS segmentation was only weakly dependent on the parameters of the initial MIP image generation, indicating the robustness of this approach. Region growing based on Z-buffer generated seeds was advantageous compared to simple thresholding. The ZBS algorithm provided segmentation accuracies similar to that obtained with the vessel enhancement filter. The ZBS performance was notably better than the filter based segmentation for aneurysms where the assumptions of the filter were violated. As currently implemented the algorithm slightly under-segments the intracranial vasculature.

Entities:  

Mesh:

Year:  2004        PMID: 15063861     DOI: 10.1016/j.media.2003.12.002

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  3 in total

1.  Interactive 3D Analysis of Blood Vessel Trees and Collateral Vessel Volumes in Magnetic Resonance Angiograms in the Mouse Ischemic Hindlimb Model.

Authors:  Peter C Marks; Marilena Preda; Terry Henderson; Lucy Liaw; Volkhard Lindner; Robert E Friesel; Ilka M Pinz
Journal:  Open Med Imaging J       Date:  2013-10-31

2.  Development of image segmentation methods for intracranial aneurysms.

Authors:  Yuka Sen; Yi Qian; Alberto Avolio; Michael Morgan
Journal:  Comput Math Methods Med       Date:  2013-03-28       Impact factor: 2.238

3.  Segmentation of Cerebrovascular Anatomy from TOF-MRA Using Length-Strained Enhancement and Random Walker.

Authors:  Ruoxiu Xiao; Cheng Chen; Hanying Zou; Ying Luo; Jiayu Wang; Muxi Zha; Ming-An Yu
Journal:  Biomed Res Int       Date:  2020-09-19       Impact factor: 3.411

  3 in total