Imaging of temperature-induced echo strain: preliminary in vitro study to assess feasibility for guiding focused ultrasound surgery.

Naomi R Miller1, Jeffrey C Bamber, Gail R ter Haar.   

Abstract

Ultrasonic estimation of heat-induced echo strain has been suggested as a noninvasive technique for guiding focused ultrasound (US) surgery (FUS), that is, for predicting the location of the thermal lesion before it is formed. The proposed strategy is to run the FUS system at a nonablative intensity and to use a diagnostic transducer to image the heat-induced echo strain, which, over a sufficiently small temperature range, is proportional to the temperature rise. The principal aim of this in vitro study was to determine if temperature-induced strain imaging is likely to be able to visualise the small (< 0.5%) strains that one would be restricted to in vivo. Temperature rises ranging from approximately 2 degrees C to 15 degrees C (starting at approximately 25 degrees C) were induced in bovine liver samples using an FUS system. The pre- and post-heated US images were processed to produce images of the apparent axial strain. These images were found to possess excellent spatial and contrast resolution, so that the hot spot remained clearly visible even when the spatial peak strain value was approximately 0.2% (corresponding to temperature rises on the order of 2 to 5 degrees C). Good repeatability in the strain images was observed within and between tissue samples. Artefacts due to thermoacoustic refraction were seen distal to the heated region, but they did not reduce hot spot visibility. The length of the hot spot exceeded that of the subsequent ablation (by approximately 200%), which was to be expected given that temperature imaging depicts the entire area over which the temperature has increased relative to the baseline. We conclude that temperature-induced strain imaging for the guidance of FUS in the liver is likely to be feasible, provided that it will be possible either to neglect or to correct for the additional sources of error (such as cardiac-induced motion) that will arise in vivo.

Entities:  

Mesh:

Year:  2004        PMID: 15063516     DOI: 10.1016/j.ultrasmedbio.2003.11.016

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  19 in total

1.  Noninvasive measurement of local thermal diffusivity using backscattered ultrasound and focused ultrasound heating.

Authors:  Ajay Anand; Peter J Kaczkowski
Journal:  Ultrasound Med Biol       Date:  2008-05-01       Impact factor: 2.998

2.  Three-dimensional electrode displacement elastography using the Siemens C7F2 fourSight four-dimensional ultrasound transducer.

Authors:  Shyam Bharat; Ted G Fisher; Tomy Varghese; Timothy J Hall; Jingfeng Jiang; Ernest L Madsen; James A Zagzebski; Fred T Lee
Journal:  Ultrasound Med Biol       Date:  2008-03-28       Impact factor: 2.998

Review 3.  Medical ultrasound: imaging of soft tissue strain and elasticity.

Authors:  Peter N T Wells; Hai-Dong Liang
Journal:  J R Soc Interface       Date:  2011-06-16       Impact factor: 4.118

4.  Thermal expansion imaging for monitoring lesion depth using M-mode ultrasound during cardiac RF ablation: in vitro study.

Authors:  Peter Baki; Sergio J Sanabria; Gabor Kosa; Gabor Szekely; Orcun Goksel
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-23       Impact factor: 2.924

Review 5.  Focused Ultrasound for Neuromodulation.

Authors:  David P Darrow
Journal:  Neurotherapeutics       Date:  2019-01       Impact factor: 7.620

6.  Thermal strain imaging: a review.

Authors:  Chi Hyung Seo; Yan Shi; Sheng-Wen Huang; Kang Kim; Matthew O'Donnell
Journal:  Interface Focus       Date:  2011-05-23       Impact factor: 3.906

Review 7.  Thermometry and ablation monitoring with ultrasound.

Authors:  Matthew A Lewis; Robert M Staruch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2015-03-10       Impact factor: 3.914

8.  Real-time feedback of histotripsy thrombolysis using bubble-induced color Doppler.

Authors:  Xi Zhang; Ryan M Miller; Kuang-Wei Lin; Albert M Levin; Gabe E Owens; Hitinder S Gurm; Charles A Cain; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2015-01-23       Impact factor: 2.998

9.  The feasibility of using thermal strain imaging to regulate energy delivery during intracardiac radio-frequency ablation.

Authors:  Chi Hyung Seo; Douglas N Stephens; Jonathan Cannata; Aaron Dentinger; Feng Lin; Suhyun Park; Douglas Wildes; Kai E Thomenius; Peter Chen; Tho Nguyen; Alan de La Rama; Jong Seob Jeong; Aman Mahajan; Kalyanam Shivkumar; Amin Nikoozadeh; Omer Oralkan; Uyen Truong; David J Sahn; Pierre T Khuri-Yakub; Matthew O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-07       Impact factor: 2.725

10.  Mean scatterer spacing estimation in normal and thermally coagulated ex vivo bovine liver.

Authors:  Nicholas Rubert; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2014-04       Impact factor: 1.578

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.