Literature DB >> 15063394

In vivo dose perturbation effects of metallic dental alloys during head and neck irradiation with intensity modulated radiation therapy.

Clifton D Fuller1, Irma Diaz, Sean X Cavanaugh, Tony Y Eng.   

Abstract

A patient with base of tongue squamous sell carcinoma, with significant CT artifact-inducing metallic alloy, non-removable dental restorations in both the mandible and maxilla was identified. Simultaneous with IMRT treatment, thermoluminescent dosimeters (TLDs) were placed in the oral cavity. After a series of three treatments, the data from the TLDs and software calculations were analyzed. Analysis of mean in vivo TLD dosimetry reveals differentials from software predicted dose calculation that fall within acceptable dose variation limits. IMRT dose calculation software is a relatively accurate predictor of dose attenuation and augmentation due to dental alloys within the treatment volume, as measured by intra-oral thermoluminescent dosimetry. IMRT represents a safe and effective methodology to treat patients with non-removable metallic dental work who have head and neck cancer.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15063394     DOI: 10.1016/j.oraloncology.2003.11.010

Source DB:  PubMed          Journal:  Oral Oncol        ISSN: 1368-8375            Impact factor:   5.337


  4 in total

1.  Are intraoral customized stents still necessary in the era of Highly Conformal Radiotherapy for Head & Neck cancer? Case series and literature review.

Authors:  P Appendino; F Della Ferrera; D Nassisi; G Blandino; E Gino; S D Solla; M G Ruo Redda
Journal:  Rep Pract Oncol Radiother       Date:  2019-08-20

2.  Feasibility of optimizing intensity-modulated radiation therapy plans based on measured mucosal dose adjacent to dental fillings and toxicity outcomes.

Authors:  Seung Won Seol; Sonya Aggarwal; Rie von Eyben; Ziwei Wang; Cato Chan; Carmen Say; Lei Xing; Wendy Hara; Yong Yang; Quynh Thu Le
Journal:  J Appl Clin Med Phys       Date:  2018-07-09       Impact factor: 2.102

3.  Effect of dental restorations and prostheses on radiotherapy dose distribution: a Monte Carlo study.

Authors:  David W H Chin; Nathaniel Treister; Bernard Friedland; Robert A Cormack; Roy B Tishler; G Mike Makrigiorgos; Laurence E Court
Journal:  J Appl Clin Med Phys       Date:  2009-02-03       Impact factor: 2.102

4.  Influence of gamma radiation on microshear bond strength and nanoleakage of nanofilled restoratives in Er, Cr:YSGG laser-prepared cavities.

Authors:  Engy Fahmy Abaza; Ahmed Abbas Zaki; Haytham Samir Moharram; Amal Alaa El Din El Batouti; Asmaa Aly Yassen
Journal:  Eur J Dent       Date:  2018 Jul-Sep
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.