Electrical impedance measurements: an objective measure of prelabor cervical change.

M P O'Connell1, N J Avis, B H Brown, S R Killick, S W Lindow.   

Abstract

OBJECTIVE: To investigate the use of electrical impedance measurements of the pregnant cervix as an objective measure of cervical favorability (Bishop score > or = 5).
METHODS: A prospective study of 86 women, investigating electrical impedance measurements of the pregnant cervix at the time of induction of labor. Transfer electrical impedance measurements were made by placing a tetrapolar pencil probe of 8 mm in diameter on the surface of the cervix. A Bishop score was determined simultaneously.
RESULTS: A mean resistivity (standard error of the mean) of 7.03 (6.01-8.04) omega(m) was measured for the unfavorable group and 5.34 (4.61-6.07) omega(m) for the favorable group. This was a statistically significant difference (p = 0.016).
CONCLUSION: We highlight the ability of this safe, painless technique to differentiate the favorable from the unfavorable cervix at induction of labor.

Entities:  

Mesh:

Year:  2003        PMID: 15061317     DOI: 10.1080/14767050412331312230

Source DB:  PubMed          Journal:  J Matern Fetal Neonatal Med        ISSN: 1476-4954


  6 in total

1.  In vivo Raman spectroscopy monitors cervical change during labor.

Authors:  Laura E Masson; Christine M O'Brien; Rekha Gautam; Giju Thomas; James C Slaughter; Mack Goldberg; Kelly Bennett; Jennifer Herington; Jeff Reese; Emad Elsamadicy; J Michael Newton; Anita Mahadevan-Jansen
Journal:  Am J Obstet Gynecol       Date:  2022-02-19       Impact factor: 10.693

2.  Novel device to trend impedance and fluorescence of the cervix for preterm birth detection.

Authors:  Mozziyar Etemadi; Philip Chung; J Alex Heller; Jonathan Liu; Rebecca Grossman-Kahn; Larry Rand; Shuvo Roy
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

3.  Comparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes.

Authors:  Saurabh V Gandhi; Dawn C Walker; Brian H Brown; Dilly O C Anumba
Journal:  Biomed Eng Online       Date:  2006-11-24       Impact factor: 2.819

4.  Reproducibility and repeatability of measuring the electrical impedance of the pregnant human cervix-the effect of probe size and applied pressure.

Authors:  Roobin P Jokhi; Vidita V Ghule; Brian H Brown; Dilly O C Anumba
Journal:  Biomed Eng Online       Date:  2009-06-17       Impact factor: 2.819

5.  Towards BirthAlert--A Clinical Device Intended for Early Preterm Birth Detection.

Authors:  Mozziyar Etemadi; Philip Chung; J Alex Heller; Jonathan A Liu; Larry Rand; Shuvo Roy
Journal:  IEEE Trans Biomed Eng       Date:  2013-07-23       Impact factor: 4.538

6.  The role of cervical Electrical Impedance Spectroscopy in the prediction of the course and outcome of induced labour.

Authors:  Roobin P Jokhi; Brian H Brown; Dilly O C Anumba
Journal:  BMC Pregnancy Childbirth       Date:  2009-09-02       Impact factor: 3.007

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.