Literature DB >> 1505997

Direct use of CT scans for hyperthermia treatment planning.

B J James1, D M Sullivan.   

Abstract

In the field of deep regional hyperthermia cancer therapy, the BSD-2000 Hyperthermia System is one of the most widely used devices. Because of the complexity of the treatment process, computer modeling has long been viewed as a desirable means of planning patient treatments. Patient-specific, three-dimensional computer modeling for treatment planning in the BSD-2000 has been in clinical use at this institution for two years. Two of the persistent problems have been the large amount of time needed to create the patient model from a computed tomography (CT) scan (one and a half days), and the lack of a way to view the large amounts of data that comprise the output of a treatment plan, i.e., the specific absorption rate (SAR) at 20,000 to 30,000 cells. Here we present a method that obtains the dielectric properties needed for hyperthermia treatment planning directly from the CT image with minimum operator interaction, a process which takes about a half day and is more accurate. Comparison is made with the previous method of drawing contours around the different tissue types. We further describe a method which displays the output as iso-SAR contours directly over the CT scan of the patient.

Entities:  

Mesh:

Year:  1992        PMID: 1505997     DOI: 10.1109/10.148392

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  3 in total

1.  Improved hyperthermia treatment control using SAR/temperature simulation and PRFS magnetic resonance thermal imaging.

Authors:  Zhen Li; Martin Vogel; Paolo F Maccarini; Vadim Stakhursky; Brian J Soher; Oana I Craciunescu; Shiva Das; Omar A Arabe; Williams T Joines; Paul R Stauffer
Journal:  Int J Hyperthermia       Date:  2010-11-11       Impact factor: 3.914

2.  Temperature superposition for fast computation of 3D temperature distributions during optimization and planning of interstitial ultrasound hyperthermia treatments.

Authors:  Vasant A Salgaonkar; Punit Prakash; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2012       Impact factor: 3.914

3.  Miniature microwave applicator for murine bladder hyperthermia studies.

Authors:  Sara Salahi; Paolo F Maccarini; Dario B Rodrigues; Wiguins Etienne; Chelsea D Landon; Brant A Inman; Mark W Dewhirst; Paul R Stauffer
Journal:  Int J Hyperthermia       Date:  2012-06-12       Impact factor: 3.914

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.